Electrical Specifications (Cont.)
Specifications apply over all line and load conditions, unless otherwise noted; boldface specifications apply over the temperature range of -40°C ≤ TCASE
≤100°C (T-Grade); all other specifications are at TCASE = 25ºC unless otherwise noted.
­Attribute
Symbol
Conditions / Notes
Min
Typ
Max
Unit
General Powertrain Specification – Forward Direction Operation (High Voltage Side to Low Voltage Side) Cont.
Effective HI Side Capacitance
(Internal)
CHI_INT
Effective Value at 384VHI_DC
0.4
µF
Effective LO Side Capacitance
(Internal)
CLO_INT
Effective Value at 12VLO_DC
238
µF
Rated LO Side Capacitance (External)
CLO_OUT_EXT
Excessive capacitance may drive module into
SC protection
1000
µF
Rated LO Side Capacitance (External),
parallel array operation
CLO_OUT_AEXT
CLO_OUT_AEXT Max = N * 0.5 * CLO_OUT_EXT MAX, where
N = the number of units in parallel
Powertrain Hardware Protection Specification – Forward Direction Operation (High Voltage Side to Low Voltage Side)
• These built-in powertrain protections are fixed in hardware and cannot be configured through PMBus™.
• When duplicated in supervisory limits, hardware protections serve a secondary role and become active when supervisory limits are
disabled through PMBus.
Auto Restart Time
HI Side Overvoltage Lockout
Threshold
HI Side Overvoltage Recovery
Threshold
HI Side Overvoltage Lockout
Hysteresis
HI Side Overvoltage Lockout
Response Time
HI Side Soft-Start Time
LO Side Overcurrent
Trip Threshold
LO Side Overcurrent
Response Time Constant
LO Side Short Circuit
Protection Trip Threshold
LO Side Short Circuit
Protection Response Time
Overtemperature Shutdown
Threshold
Startup into a persistent fault condition. Non-latching
tAUTO_RESTART fault detection given VHI_DC > VHI_UVLO+
290
360
ms
VHI_OVLO+
430
440
450
V
VHI_OVLO-
410
430
440
V
VHI_OVLO_HYST
10
V
tHI_OVLO
100
µs
tHI_SOFT-START
From powertrain active. Fast current limit protection
disabled during soft-start
1
ms
ILO_OUT_OCP
135
170
210
A
tLO_OUT_OCP Effective internal RC filter
3
ms
ILO_OUT_SCP
187
A
tLO_OUT_SCP
1
µs
tOTP+
Internal
125
°C
BCM® in a VIA Package
Page 7 of 42
Rev 1.5
10/2016
vicorpower.com
800 927.9474