English
Language : 

BCM4414XD1E13A2YZZ Datasheet, PDF (25/42 Pages) Vicor Corporation – Isolated Fixed-Ratio DC-DC Converter
System Diagram for PMBus™ Interface
5V
EXT_BIAS
SCL
BCM in a VIA
SDA
Package
SGND
ADDR
BCM4414xD1E13A2yzz
SCL
SDA
SGND
Host
PMBus™
The controller of the BCM in a VIA package is referenced to low voltage side signal ground (SGND).
The BCM in a VIA package provides the Host PMBus system with accurate telemetry monitoring and reporting, threshold and
warning limits adjustment, in addition to corresponding status flags. The standalone BCM is periodically polled for status by the host
PMBus. Direct communication to the BCM is enabled by a page command. For example, the page (0x00) prior to a telemetry inquiry
points to the controller data and pages (0x01) prior to a telemetry inquiry points to the BCM parameters. The BCM constantly polls
its data through the PMBus.
The BCM enables the PMBus compatible host interface with an operating bus speed of up to 400kHz. The BCM follows the PMBus
command structure and specification.
BCM® in a VIA Package
Page 25 of 42
Rev 1.5
10/2016
vicorpower.com