BCM4414XD1E13A2YZZ Datasheet, PDF (34/42 Pages) Vicor Corporation – Isolated Fixed-Ratio DC-DC Converter
STATUS_INPUT (7Ch)
VIN_OV_FAULT
VIN_OV_WARNING
Not Supported: VIN_UV_WARNING
VIN_UV_FAULT
Not Supported: Unit Off For Insufficient
Input Voltage
Not Supported: IIN_OC_FAULT
Not Supported: IIN_OC_WARNING
Not Supported: PIN_OP_WARNING
76543210
11010000b
Unsupported bits are indicated above. A one indicates a fault.
STATUS_TEMPERATURE (7Dh)
OT_FAULT
OT_WARNING
Not Supported: UT_WARNING
UT_FAULT
Reserved
Reserved
Reserved
Reserved
76543210
11010000b
Unsupported bits are indicated above. A one indicates a fault.
STATUS_CML (7Eh)
Invalid Or Unsupported Command Received
Invalid Or Unsupported Data Received
Not Supported: Packet Error Check Failed
Not Supported: Memory Fault Detected
Not Supported: Processor Fault Detected
Reserved
Other Communication Faults
Not Supported: Other Memory Or Logic
Fault
76543210
11000010b
Unsupported bits are indicated above. A one indicates a fault.
BCM® in a VIA Package
Page 34 of 42
Rev 1.5
10/2016
BCM4414xD1E13A2yzz
The STATUS_CML data byte will be asserted when an unsupported
PMBus™ command or data or other communication fault occurs.
STATUS_MFR_SPECIFIC (80h)
Reserved
Reserved
Reserved
Reserved
PAGE Data Byte = (01h)
Reserved
BCM UART CML
Hardware Protections Shutdown Fault
BCM Reverse Operation
76543210
00000111b
The reverse operation bit, if asserted, indicates that the BCM is
processing current in reverse. Reverse current reported value is
not supported.
The BCM has hardware protections and supervisory limits. The
hardware protections provide an additional layer of protection
and have the fastest response time. The Hardware Protections
Shutdown Fault, when asserted, indicates that at least one of the
powertrain protection faults is triggered. This fault will also be
asserted if a disabled fault event occurs after asserting any bit using
the DISABLE_FAULTS COMMAND.
The BCM UART is designed to operate with the controller UART.
If the BCM UART CML is asserted, it may indicate a hardware or
connection issue between both devices.
Reserved
Reserved
Reserved
PAGE Data Byte = (00h)
BCM at PAGE (01h) is present
Reserved
BCM UART CML
Hardware Protections Shutdown Fault
BCM Reverse Operation
76543210
00000000b
When the PAGE COMMAND (00h) data byte is equal to (00h), the
BCM Reverse operation, Analog Controller Shutdown Fault, and
BCM UART CML bit will return the result of the active BCM. The
BCM UART CML will also be asserted if the active BCM
stops responding. The BCM must communicate at least once
to the internal controller in order to trigger this FAULT. The BCM
UART CML can be cleared using the PAGE (00h) CLEAR_FAULTS
(03h) Command.