English
Language : 

DS99R124AQ_14 Datasheet, PDF (9/31 Pages) Texas Instruments – 5 - 43 MHz 18-bit Color FPD-Link II to FPD-Link Converter
DS99R124AQ
www.ti.com
SNLS342A – JULY 2011 – REVISED APRIL 2013
Recommended Timing for the Serial Control Bus
Over recommended operating supply and temperature ranges unless otherwise specified.
Parameter
Test Conditions
Min
fSCL
SCL Clock Frequency
Standard Mode
0
Fast Mode
0
tLOW
SCL Low Period
Standard Mode
4.7
Fast Mode
1.3
tHIGH
SCL High Period
Standard Mode
4.0
Fast Mode
0.6
tHD;STA Hold time for a start or a
Standard Mode
4.0
repeated start condition,
Figure 13
Fast Mode
0.6
tSU:STA Set Up time for a start or a
Standard Mode
4.7
repeated start condition,
Figure 13
Fast Mode
0.6
tHD;DAT Data Hold Time, Figure 13
Standard Mode
0
Fast Mode
0
tSU;DAT Data Set Up Time, Figure 13
Standard Mode
250
Fast Mode
100
tSU;STO Set Up Time for STOP
Standard Mode
4.0
Condition, Figure 13
Fast Mode
0.6
tBUF
Bus Free Time Between STOP Standard Mode
4.7
and START, Figure 13
Fast Mode
1.3
tr
SCL and SDA Rise Time,
Standard Mode
Figure 13
Fast Mode
tf
SCL and SDA Fall Time,
Figure 13
Standard Mode
Fast mode
Typ
Max Units
100 kHz
400 kHz
us
us
us
us
us
us
us
us
3.45
us
0.9
us
ns
ns
us
us
us
us
1000 ns
300
ns
300
ns
300
ns
DC and AC Serial Control Bus Characteristics
Over recommended operating supply and temperature ranges unless otherwise specified.
Parameter
Test Conditions
VIH
Input High Level
SDA and SCL
VIL
Input Low Level Voltage
SDA and SCL
VHY
VOL
Iin
tR
tF
tSU;DAT
tHD;DAT
tSP
Cin
Input Hysteresis
SDA RiseTime – READ
SDA Fall Time – READ
Set Up Time — READ
Hold Up Time — READ
Input Filter
Input Capacitance
SDA, IOL = +0.5 mA
SDA or SCL, Vin = VDDIO or GND
SDA, RPU = X, Cb ≤ 400pF
SDA or SCL
Min
0.7*
VDDIO
GND
0
-10
Typ
Max Units
VDDIO
V
0.3*
VDDIO
V
>50
mV
0.36
V
+10
µA
800
ns
50
ns
540
ns
600
ns
50
ns
<5
pF
Copyright © 2011–2013, Texas Instruments Incorporated
Product Folder Links: DS99R124AQ
Submit Documentation Feedback
9