English
Language : 

SN74AUP1G126_17 Datasheet, PDF (8/40 Pages) Texas Instruments – Low-Power Single Bus Buffer Gate With 3-State Output
SN74AUP1G126
SCES596G – JULY 2004 – REVISED AUGUST 2017
www.ti.com
6.7 Switching Characteristics: CL = 10 pF
over recommended operating free-air temperature range, CL = 10 pF (unless otherwise noted) (see Figure 2 and Figure 3)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
TEST CONDITIONS
MIN TYP MAX UNIT
VCC = 0.8 V
TA = 25°C
20.5 13.7
VCC = 1.2 V ± 0.1 V
TA = 25°C
TA = –40°C to +85°C
4.6 8.4 9.3
3.6
16.6
VCC = 1.5 V ± 0.1 V
TA = 25°C
TA = –40°C to +85°C
3.5 5.9 7.5
2.4
11.1
tpd
A or B
Y
VCC = 1.8 V ± 0.15 V
TA = 25°C
TA = –40°C to +85°C
3.9 4.7 5.3 ns
1.3
9.1
VCC = 2.5 V ± 0.2 V
TA = 25°C
TA = –40°C to +85°C
2.3 3.4 4.3
1.6
6.4
VCC = 3.3 V ± 0.3 V
TA = 25°C
TA = –40°C to +85°C
2.1 2.8
1.4
5.2
VCC = 0.8 V
TA = 25°C
21.8 16.8
VCC = 1.2 V ± 0.1 V
TA = 25°C
TA = –40°C to +85°C
4.9 10.2 11.2
4.4
20.2
VCC = 1.5 V ± 0.1 V
TA = 25°C
TA = –40°C to +85°C
3.9 7.3 9.2
3.3
13.5
ten
OE
Y
VCC = 1.8 V ± 0.15 V
TA = 25°C
TA = –40°C to +85°C
3.4 5.8 6.4 ns
2.7
11
VCC = 2.5 V ± 0.2 V
TA = 25°C
TA = –40°C to +85°C
2.5 4.3 5.4
2.1
7.8
VCC = 3.3 V ± 0.3 V
TA = 25°C
TA = –40°C to +85°C
2.1 3.7
1.9
6.4
VCC = 0.8 V
TA = 25°C
13
VCC = 1.2 V ± 0.1 V
TA = 25°C
TA = –40°C to +85°C
3.8 6.6 11.7
1.2
14
VCC = 1.5 V ± 0.1 V
TA = 25°C
TA = –40°C to +85°C
2.2 4.7 7.9
1.3
9.3
tdis
OE
Y
VCC = 1.8 V ± 0.15 V
TA = 25°C
TA = –40°C to +85°C
2.4 4.4 6.4 ns
2.2
7.5
VCC = 2.5 V ± 0.2 V
TA = 25°C
TA = –40°C to +85°C
1.3 3.1 4.9
1.2
5.4
VCC = 3.3 V ± 0.3 V
TA = 25°C
TA = –40°C to +85°C
1.9 3.4
5
1.9
5.6
8
Submit Documentation Feedback
Copyright © 2004–2017, Texas Instruments Incorporated
Product Folder Links: SN74AUP1G126