English
Language : 

LM3S9B95-IQC80-C3 Datasheet, PDF (677/1401 Pages) Texas Instruments – Stellaris® LM3S9B95 Microcontroller
NRND: Not recommended for new designs.
Stellaris® LM3S9B95 Microcontroller
Bit/Field
5
4
3
2
Name
DCINT5
DCINT4
DCINT3
DCINT2
Type
R/W
R/W
R/W
R/W
Reset
0
0
0
0
Description
Digital Comparator Interrupt 5
Value Description
1 Resets the Digital Comparator 5 interrupt unit to its initial
conditions.
0 No effect.
When the interrupt has been cleared, this bit is automatically cleared.
Because the digital comparators use the current and previous ADC
conversion values to determine when to assert the interrupt, it is
important to reset the digital comparator to initial conditions when starting
a new sequence so that stale data is not used.
Digital Comparator Interrupt 4
Value Description
1 Resets the Digital Comparator 4 interrupt unit to its initial
conditions.
0 No effect.
When the interrupt has been cleared, this bit is automatically cleared.
Because the digital comparators use the current and previous ADC
conversion values to determine when to assert the interrupt, it is
important to reset the digital comparator to initial conditions when starting
a new sequence so that stale data is not used.
Digital Comparator Interrupt 3
Value Description
1 Resets the Digital Comparator 3 interrupt unit to its initial
conditions.
0 No effect.
When the interrupt has been cleared, this bit is automatically cleared.
Because the digital comparators use the current and previous ADC
conversion values to determine when to assert the interrupt, it is
important to reset the digital comparator to initial conditions when starting
a new sequence so that stale data is not used.
Digital Comparator Interrupt 2
Value Description
1 Resets the Digital Comparator 2 interrupt unit to its initial
conditions.
0 No effect.
When the interrupt has been cleared, this bit is automatically cleared.
Because the digital comparators use the current and previous ADC
conversion values to determine when to assert the interrupt, it is
important to reset the digital comparator to initial conditions when starting
a new sequence so that stale data is not used.
October 05, 2012
677
Texas Instruments-Production Data