English
Language : 

AM1806_16 Datasheet, PDF (61/245 Pages) Texas Instruments – AM1806 ARM® Microprocessor
www.ti.com
AM1806
SPRS658F – FEBRUARY 2010 – REVISED MARCH 2014
Recommended Operating Conditions (continued)
NAME
DESCRIPTION
CONDITION
MIN
NOM
MAX
UNIT
Transition
Time
tt
Transition time, 10%-90%, All Inputs (unless otherwise
specified in the electrical data sections)
0.25P or 10 (5)
ns
CVDD = 1.3V
operating point
0
456
Commercial temperature grade
CVDD = 1.2V
operating point
0
(default)
CVDD = 1.1V
operating point
0
375
MHz
200
Operating
Frequency
FPLL0_SYSCLK6
CVDD = 1.0V
operating point
0
100
CVDD = 1.3V
operating point
0
456
Extended temperature grade (A
CVDD = 1.2V
operating point
0
suffix)
CVDD = 1.1V
operating point
0
375
MHz
200
CVDD = 1.0V
operating point
0
100
(5) Whichever is smaller. Where P = the period of the applied signal. Maintaining transition times as fast as possible is recommended to
improve noise immunity on input signals.
Copyright © 2010–2014, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: AM1806
Specifications
61