TIBPSG507AC Datasheet, PDF (6/19 Pages) Texas Instruments – 13 × 80 × 8 PROGRAMMABLE SEQUENCE GENERATOR | |||
|
◁ |
TIBPSG507AC
13 Ã 80 Ã 8 PROGRAMMABLE SEQUENCE GENERATOR
SRPS002D â D3029, MAY 1987 â REVISED NOVEMBER 1995
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage, VCC (see Note 3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V
Input voltage (see Note 3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.5 V
Voltage applied to disabled output (see Note 3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.5 V
Operating free-air temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to 75°C
Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . â 65°C to 150°C
NOTE 3: These ratings apply except for programming pins during a programming cycle or during the diagnostic mode.
recommended operating conditions
MIN NOM MAX UNIT
VCC
VIH
Supply voltage
High-level input voltage
4.75
5 5.25 V
2
5.5 V
VIL
Low-level input voltage
IOH
High-level output current
IOL
Low-level output current
0.8 V
â 3.2 mA
16 mA
tw
Pulse duration
Clock high
Clock low
6
ns
6
Input or feedback to S/Râ inputs
12
tsu
Setup time before CLK active transitionâ
Input or feedback to S/Râ inputsâ¡
Input or feedback to SCLR0
19
20
ns
Input or feedback to CNT/HLD0
25
Input or feedback at S/R inputs
0
th
Hold time after CLK active transitionâ
Input or feedback at SCLR0
0
ns
Input or feedback at CNT/HLD0
0
TA
Operating free-air temperature
0
25
75 °C
â Internal setup and hold times, tsu feedback to SCLR1, feedback to CNT/HLD1; th feedback at SCLR1 and feedback at CNT/HLD1, are
guaranteed by fmax specifications. The active transition of CLK is determined by the programmed state of the CLK polarity fuse.
â¡ See the OR term loading section and Figure 3.
6
⢠POST OFFICE BOX 655303 DALLAS, TEXAS 75265
|
▷ |