English
Language : 

LM3S618 Datasheet, PDF (528/572 Pages) List of Unclassifed Manufacturers – Microcontroller
Electrical Characteristics
Figure 19-1. Load Conditions
pin
CL = 50 pF
GND
19.2.2 Clocks
Table 19-7. Phase Locked Loop (PLL) Characteristics
Parameter Parameter Name
Min
Nom
Max
Unit
fref_crystal
fref_ext
fpll
Crystal referencea
External clock referencea
PLL frequencyb
3.579545
-
3.579545
-
-
200
8.192
8.192
-
MHz
MHz
MHz
TREADY
PLL lock time
-
-
0.5
ms
a. The exact value is determined by the crystal value programmed into the XTAL field of the Run-Mode Clock Configuration
(RCC) register.
b. PLL frequency is automatically calculated by the hardware based on the XTAL field of the RCC register.
Table 19-8. Clock Characteristics
Parameter
Parameter Name
Min
Nom
Max
fIOSC
fMOSC
tMOSC_per
fref_crystal_bypass
Internal oscillator frequency
7
12
Main oscillator frequency
1
-
Main oscillator period
125
-
Crystal reference using the main oscillator
1
-
(PLL in BYPASS mode)a
22
8
1000
8
fref_ext_bypass
External clock reference (PLL in BYPASS
0
-
50
mode)a
fsystem_clock
System clock
0
-
50
a. The ADC must be clocked from the PLL or directly from a 16.667-MHz clock source to operate properly.
19.2.2.1 System Clock Specifications with ADC Operation
Unit
MHz
MHz
ns
MHz
MHz
MHz
Table 19-9. System Clock Characteristics with ADC Operation
Parameter Parameter Name
Min
fsysadc
System clock frequency when the ADC module is
16
operating (when PLL is bypassed)
Nom
Max
-
-
Unit
MHz
19.2.3 JTAG and Boundary Scan
Table 19-10. JTAG Characteristics
Parameter
No.
J1
J2
Parameter Parameter Name
fTCK
TCK operational clock frequency
tTCK
TCK operational clock period
Min
Nom
Max
0
-
10
100
-
-
Unit
MHz
ns
528
July 14, 2014
Texas Instruments-Production Data