English
Language : 

TMS320F28075 Datasheet, PDF (52/182 Pages) Texas Instruments – Microcontrollers
TMS320F28075
SPRS902B – OCTOBER 2014 – REVISED OCTOBER 2015
www.ti.com
5.7.3.5 Internal Oscillators
To reduce production board costs and application development time, all F2807x devices contain two
independent internal oscillators, referred to as INTOSC1 and INTOSC2. By default, both oscillators are
enabled at power up. INTOSC2 is set as the source for the system reference clock (OSCCLK) and
INTOSC1 is set as the backup clock source. INTOSC1 can also be manually configured as the system
reference clock (OSCCLK). Table 5-18 provides the electrical characteristics of the internal oscillators to
determine if this module meets the clocking requirements of the application.
Table 5-18 provides the electrical characteristics of the two internal oscillators.
Table 5-18. Internal Oscillator Electrical Characteristics
over recommended operating conditions (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN
TYP
f(INTOSC)
Frequency, INTOSC1 and INTOSC2
Frequency stability at room temperature 30°C
9.7
±0.1%
tOSCST
Start-up and settling time
MAX
10.3
UNIT
MHz
22
µs
52
Specifications
Copyright © 2014–2015, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: TMS320F28075