CONFIG1: Configuration Register 1
Address = 01h
BIT 7
SINGLE_SHOT
BIT 6
0
BIT 5
0
BIT 4
0
BIT 3
0
BIT 2
DR2
This register configures each ADC channel sample rate.
Bit 7
Bits[6:3]
Bits[2:0]
SINGLE_SHOT: Single-shot conversion
This bit sets the conversion mode
0 = Continuous conversion mode (default)
1 = Single-shot mode
Must be set to '0'
DR[2:0]: Channel oversampling ratio
These bits determine the oversampling ratio of both channel 1 and channel 2.
BIT
OVERSAMPLING RATIO DATA RATE(1)
000
fMOD / 1024
125 SPS
001
fMOD / 512
250 SPS
010
fMOD / 256
500 SPS (default)
011
fMOD / 128
1 kSPS
100
fMOD / 64
2 kSPS
101
fMOD / 32
4 kSPS
110
fMOD / 16
8 kSPS
111
Do not use
Do not use
(1) fCLK = 512 kHz and CLK_DIV = 0 or fCLK = 2.048 MHz and CLK_DIV = 1.
BIT 1
DR1
www.ti.com
BIT 0
DR0