BQ25872 Datasheet, PDF (36/68 Pages) Texas Instruments – Battery Switch Charger | |||
|
◁ |
bq25872
SLUSCQ6 â OCTOBER 2016
www.ti.com
8.5.8 REG06 (CONTROL)
Figure 27. REG06 (CONTROL)
7
6
5
4
3
2
1
0
0
0
1
0
0
1
0
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
LEGEND: R/W = Read/Write; R = Read only; -n = value after reset
Table 9. REG06 (CONTROL)
Bit Field
7 VDROP_OVP_EN
6 VDROP_ALM_EN
5 SENSE_R
4 CHG_EN
3 WATCHDOG[1]
2 WATCHDOG[0]
1 RCP_SET
0 REG_RST
Reset
Type
Description
REG_RST Watchdog EN
Enables VDROP_OVP protection
R/W
Y
N
Y
0 â disable VDROP_OVP protection (default)
1 â enable VDROP_OVP protection
Enables VDROP_ALM protection
R/W
Y
N
Y
0 â disable VDROP_ALM protection (default)
1 â enable VDROP_ALM protection
Select the sense resistor value between SRP and SRN
R/W
Y
N
Y
0 â 5 mΩ
1 â 10 mΩ (default)
Software bit for charge enable. This enables the battery
switch. This bit will set to '0' if any fault causes the battery
R/W
Y
Y
Y
switch to be disabled.
0 â charge disabled (default)
1 â charge enabled
R/W
Y
N
Y
Watchdog timer setting
00 â disable watchdog timer
01 â 0.5 s
R/W
Y
N
Y
10 â 1.0 s (default)
11 â 2 s
Reverse current protection (RCP) threshold setting
R/W
Y
N
Y
0 â RCP set to 0 A (default)
1 â RCP set to -3 A
Register reset
R/W
Y
N
Y
0 â no reset (default)
1 â reset all registers to default values
36
Submit Documentation Feedback
Product Folder Links: bq25872
Copyright © 2016, Texas Instruments Incorporated
|
▷ |