English
Language : 

BQ25872 Datasheet, PDF (21/68 Pages) Texas Instruments – Battery Switch Charger
www.ti.com
bq25872
SLUSCQ6 – OCTOBER 2016
Feature Description (continued)
8.3.5.4 IBUS and VBUS Protection
Over-current protection on VBUS (IBUS_OCP) monitors the current flow from VBUS to VOUT pins. IBUS_OCP
protection is always active when the battery switch is enabled, and the protection has a deglitch time that
depends on the OCP_RES setting as described below.
If OCP_RES = ‘0’ (blanking mode), the device will wait tIBUS_OCP_BLANK before disabling the battery switch within
tOFF_FET and setting CHG_EN to ‘0’. When the battery switch is disabled, IBUS_OCP_FLT is set to ‘1’. If during
the tIBUS_OCP_BLANK duration a short circuit protection scenario occurs, then the device will follow the behavior as
listed in short circuit protection (SCP). Once the battery switch is disabled, CHG_EN is set to ‘0’ and host
intervention is required to set CHG_EN to ‘1’ to enable the battery switch again.
IBUS_OCP
ISCP
IBUS_OCP
tSCP
ISCP
IBUS
IBUS
tOFF_FET
VOUT
VOUT
tIBUS_OCP_BLANK
tIBUS_OCP_BLANK
time starts here
Figure 11. IBUS OCP and SCP
tOFF_FET
Copyright © 2016, Texas Instruments Incorporated
Product Folder Links: bq25872
Submit Documentation Feedback
21