Table 5-20 lists the linearity parameters of the ADC.
Table 5-20. ADC, 10-Bit Linearity Parameters
Over operating free-air temperature range (unless otherwise noted)
PARAMETER
TEST CONDITIONS
VCC
MIN TYP MAX UNIT
Integral linearity error (10-bit mode)
EI
Integral linearity error (8-bit mode)
Veref+ reference
2.4 V to 3.6 V
–2
2.0 V to 3.6 V
–2
2
LSB
2
Differential linearity error (10-bit mode)
ED
Differential linearity error (8-bit mode)
Veref+ reference
2.4 V to 3.6 V
–1
2.0 V to 3.6 V
–1
1
LSB
1
Offset error (10-bit mode)
EO
Offset error (8-bit mode)
Veref+ reference
2.4 V to 3.6 V –6.5
2.0 V to 3.6 V –6.5
6.5
mV
6.5
Gain error (10-bit mode)
EG
Gain error (8-bit mode)
Veref+ as reference
Internal 1.5-V reference
Veref+ as reference
Internal 1.5-V reference
2.4 V to 3.6 V
2.0 V to 3.6 V
–2.0
–3.0%
–2.0
–3.0%
2.0 LSB
3.0%
2.0 LSB
3.0%
Veref+ as reference
–2.0
2.0 LSB
Total unadjusted error (10-bit mode)
2.4 V to 3.6 V
Internal 1.5-V reference
–3.0%
3.0%
ET
Veref+ as reference
–2.0
2.0 LSB
Total unadjusted error (8-bit mode)
2.0 V to 3.6 V
Internal 1.5-V reference
–3.0%
3.0%
VSENSOR
TCSENSOR
See (1)
See (2)
tSENSOR
(sample)
Sample time required if channel 12 is
selected
ADCON = 1, INCH = 0Ch,
TA = 0℃
ADCON = 1, INCH = 0Ch
ADCON = 1, INCH = 0Ch,
Error of conversion result
≤1 LSB, AM and all LPMs
above LPM3
ADCON = 1, INCH = 0Ch,
Error of conversion result
≤1 LSB, LPM3
3.0 V
3.0 V
3.0 V
3.0 V
913
3.35
30
100
mV
mV/℃
µs
(1) The temperature sensor offset can vary significantly. TI recommends a single-point calibration to minimize the offset error of the built-in
temperature sensor.
(2) The device descriptor structure contains calibration values for 30℃ ±3℃ and 85°C ±3℃ for each available reference voltage level. The
sensor voltage can be computed as VSENSE = TCSENSOR × (Temperature, ℃ ) + VSENSOR , where TCSENSOR and VSENSOR can be
computed from the calibration values for higher accuracy.
Copyright © 2016, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: MSP430FR2111 MSP430FR2110
Specifications
29