Absolute Maximum Ratings(1)
Voltage applied at VCC to VSS
Voltage applied to any pin(2)
Diode current at any device terminal
Tstg
Storage temperature(3)
Unprogrammed device
Programmed device
-0.3 V to 4.1 V
-0.3 V to VCC + 0.3 V
±2 mA
-55°C to 150°C
-55°C to 150°C
(1) Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating
conditions" is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) All voltages referenced to VSS. The JTAG fuse-blow voltage, VFB, is allowed to exceed the absolute maximum rating. The voltage is
applied to the TEST pin when blowing the JTAG fuse.
(3) Higher temperature may be applied during board soldering according to the current JEDEC J-STD-020 specification with peak reflow
temperatures not higher than classified on the device label on the shipping boxes or reels.
Recommended Operating Conditions
VCC Supply voltage
VSS Supply voltage
TA
Operating free-air temperature
fSYSTE Processor frequency (maximum MCLK frequency)(1)(2)
M
During program execution
During flash program/erase
I version
T version
VCC = 1.8 V,
Duty cycle = 50% ± 10%
VCC = 2.7 V,
Duty cycle = 50% ± 10%
VCC ≥ 3.3 V,
Duty cycle = 50% ± 10%
MIN NOM MAX UNIT
1.8
3.6
V
2.2
3.6
0
V
-40
85
°C
-40
105
dc
6
dc
12 MHz
dc
16
(1) The MSP430 CPU is clocked directly with MCLK. Both the high and low phase of MCLK must not exceed the pulse width of the
specified maximum frequency.
(2) Modules might have a different maximum input clock specification. See the specification of the respective module in this data sheet.
16 MHz
12 MHz
6 MHz
Legend :
Supply voltage range,
during flash memory
programming
Supply voltage range,
during program execution
1.8 V 2.2 V
2.7 V
3.3 V 3.6 V
Supply Voltage −V
Note: Minimum processor frequency is defined by system clock. Flash program or erase operations require a minimum VCC
of 2.2 V.
Figure 1. Safe Operating Area