English
Language : 

CC1310_16 Datasheet, PDF (20/54 Pages) Texas Instruments – SimpleLink Ultralow Power Sub-1-GHz Wireless MCU
CC1310
SWRS181B – SEPTEMBER 2015 – REVISED OCTOBER 2015
www.ti.com
5.10.6 Temperature Sensor
Measured on the Texas Instruments CC1310EM-7XD-7793 reference design with Tc = 25°C, VDDS = 3.0 V, unless otherwise
noted.
PARAMETER
TEST CONDITIONS
MIN TYP MAX
UNIT
Resolution
4
°C
Range
–40
85
°C
Accuracy
Supply voltage coefficient(1)
±5
°C
3.2
°C/V
(1) Automatically compensated when using supplied driver libraries.
5.10.7 Battery Monitor
Measured on the Texas Instruments CC1310EM-7XD-7793 reference design with Tc = 25°C, VDDS = 3.0 V, unless otherwise
noted.
PARAMETER
TEST CONDITIONS
MIN TYP MAX
UNIT
Resolution
50
mV
Range
1.8
3.8
V
Accuracy
13
mV
5.10.8 Continuous Time Comparator
Tc = 25°C, VDDS = 3.0 V, unless otherwise noted.
PARAMETER
TEST CONDITIONS
Input voltage range
External reference voltage
Internal reference voltage
DCOUPL as reference
Offset
Hysteresis
Decision time
Current consumption when enabled(1)
Step from –10 mV to 10 mV
(1) Additionally, the bias module must be enabled when running in standby mode.
5.10.9 Low-Power Clocked Comparator
Tc = 25°C, VDDS = 3.0 V, unless otherwise noted.
PARAMETER
TEST CONDITIONS
Input voltage range
Clock frequency
Internal reference voltage, VDDS / 2
Internal reference voltage, VDDS / 3
Internal reference voltage, VDDS / 4
Internal reference voltage, DCOUPL / 1
Internal reference voltage, DCOUPL / 2
Internal reference voltage, DCOUPL / 3
Internal reference voltage, DCOUPL / 4
Offset
Hysteresis
Decision time
Step from –50 mV to 50 mV
Current consumption when enabled
MIN TYP MAX
UNIT
0
VDDS
V
0
VDDS
V
1.27
V
3
mV
<2
mV
0.72
µs
8.6
µA
MIN
TYP
0
32.8
1.49 – 1.51
1.01 – 1.03
0.78 – 0.79
1.25 – 1.28
0.63 – 0.65
0.42 – 0.44
0.33 – 0.34
<2
<5
1
362
MAX
VDDS
UNIT
V
kHz
V
V
V
V
V
V
V
mV
mV
clock-cycle
nA
20
Specifications
Submit Documentation Feedback
Product Folder Links: CC1310