English
Language : 

BQ29312_15 Datasheet, PDF (20/39 Pages) Texas Instruments – FOUR CELL LITHIUM-ION
bq29312
SLUS546E – MARCH 2003 – REVISED MARCH 2005
CELL SEL: Cell Select Register
7
6
5
CB3
CB2
CB1
CELL_SEL REGISTER (0x04)
4
3
CB0
CAL1
2
CAL0
www.ti.com
1
CELL1
0
CELL0
This register determines cell selection for voltage measurement and translation, cell balancing and the
operational mode of the cell voltage monitoring.
CELL_SEL b0–b1 (CELL0–CELL1): These two bits select the series cell for voltage measurement translation.
CELL1
0
0
1
1
CELL0
0
1
0
1
SELECTED CELL
VC4–VC5, Bottom series element (Default)
VC4–VC3, Second lowest series element
VC3–VC2, Second highest series element
VC1–VC2, Top series element
CELL_SEL b2–b3 (CAL1, CAL0): These bits determine the mode of the voltage monitor block.
CAL1
0
0
1
1
CAL0
0
1
0
1
SELECTED MODE
Cell translation for selected cell (default)
Offset measurement for selected cell
Monitor the VREF value for gain calibration
Monitor the VREF directly value for gain calibration, bypassing the translation circuit
CELL_SEL b4–b7 (CB0–CB3): These 4 bits select the series cell for cell balance bypass path.
CELL SEL b4 (CB0): This bit enables or disables the bottom series cell balance charge bypass path
0 = disable bottom series cell balance charge bypass path (default).
1 = enable bottom series cell balance charge bypass path.
CELL SEL b5 (CB1): This bit enables or disables the second lowest series cell balance charge bypass path.
0 = disable series cell balance charge bypass path (default).
1 = enable series cell balance charge bypass path.
CELL SEL b6 (CB2): This bit enables or disables the second highest cell balance charge bypass path.
0 = disable series cell balance charge bypass path (default).
1 = enable series cell balance charge bypass path.
CELL SEL b7 (CB3): This bit enables or disables the highest series cell balance charge bypass path.
0 = disable series cell balance charge bypass path (default).
1 = enable series cell balance charge bypass path.
20