English
Language : 

THS10082_09 Datasheet, PDF (17/37 Pages) Texas Instruments – 10-BIT, TWO ANALOG INPUT, 8-MSPS, SIMULTANAEOUS SAMPLING
www.ti.com
THS10082
SLAS254B − MAY 2002 − REVISED NOVEMBER 2002
Sample N Sample N+1 Sample N+2 Sample N+3 Sample N+4 Sample N+5 Sample N+6 Sample N+7 Sample N+8
Channel 1 Channel 1 Channel 1 Channel 1 Channel 1 Channel 1 Channel 1 Channel 1 Channel 1
AIN
tw(CONV_CLKH)
CONV_CLK
Data Into
FIFO
td(A)
td(pipe)
tw(CONV_CLKL)
50%
50%
tc
Data N−5
Channel 1
Data N−4 Data N−3
Channel 1 Channel 1
DATA_AV,
Trigger Level = 1
DATA_AV,
Trigger Level = 4
td(O)
Data N−2 Data N−1
Channel 1 Channel 1
Data N
Channel 1
Data N+1 Data N+2
Channel 1 Channel 1
td(DATA_AV)
Data N+3
Channel 1
td(DATA_AV)
Figure 27. Timing of Continuous Conversion Mode (1-channel operation)
Figure 28 shows the timing of continuous conversion mode when two analog input channels are selected. The maximum
throughput rate per channel is 4 MSPS in this mode. The data flow in the bottom of the figure shows the order the converted
data is written into the FIFO. The timing of the DATA_AV signal shown here is for a trigger level set to 2 or 4.
Sample N
Channel 1,2
AIN
Sample N+1
Channel 1,2
Sample N+2
Channel 1,2
Sample N+3
Channel 1,2
Sample N+4
Channel 1,2
tw(CONV_CLKH)
CONV_CLK
td(A)
td(Pipe)
tw(CONV_CLKL)
50%
50%
tc
Data Into
FIFO
Data N−3
Channel 2
Data N−2 Data N−2
Channel 1 Channel 2
DATA_AV,
Trigger Level = 2
td(O)
Data N−1 Data N−1
Channel 1 Channel 2
Data N
Channel 1
Data N
Channel 2
Data N+1
Channel 1
Data N+1
Channel 2
td(DATA_AV)
td(DATA_AV)
DATA_AV,
Trigger Level = 4
Figure 28. Timing of Continuous Conversion Mode (2-Channel Operation)
17