|
TCM8002_08 Datasheet, PDF (16/25 Pages) Texas Instruments – DATA PROCESSOR FOR CELLULAR TELEPHONE | |||
|
◁ |
TCM8002
DATA PROCESSOR FOR CELLULAR TELEPHONE
SLWS008C â SEPTEMBER 1994 â REVISED JUNE 1996
PRINCIPLES OF OPERATION
Table 8. Address 03 â Interrupt-Control Word 1
BIT
INTERRUPT ENABLED
(WHEN BIT IS SET)
0 RX data available
1 TX buffer available
2 Arbitration failure
3 TX sequence completed
4 Change of RECC bus/idle status
5 Counter/timer reaches zero state
6 SAT measurement decision changes
Table 9. Address 04 â Interrupt-Control Word 2
BIT
INTERRUPT ENABLED
(WHEN BIT IS SET)
0 TCM8010 interface activity completed
1 FVC dotting detected
2 FVC frame sync achieved
3 Change of FOCC frame-sync status
4 SAT measurement update (every 0.2 seconds)
Table 10. Address 05 â PIO1 Control Word
BIT (0 â7)
0
1
CORRESPONDING TERMINAL FUNCTION
(0 â7)
Input
Output
The eight terminals of the port are configured as inputs by default. The terminals have programmable 10-µA
pullups that can be disabled using bit 4 of control word 2.
address 06 â PIO1 output word
This sets the state of the PIO1 terminals when configured as outputs.
address 07 â PIO2 control word
This selects whether the individual port 2 terminals are configured as inputs or outputs.
address 08 â PIO2 output word
This sets the state of the PIO2 terminals when configured as outputs.
address 09 â PIO3 control word
This selects whether the individual port 3 terminals are configured as inputs or outputs.
16
⢠POST OFFICE BOX 655303 DALLAS, TEXAS 75265
⢠POST OFFICE BOX 1443 HOUSTON, TEXAS 77251â1443
|
▷ |