English
Language : 

DS90UR903Q Datasheet, PDF (14/34 Pages) Texas Instruments – DS90UR903Q/DS90UR904Q 10 - 43MHz 18 Bit Color FPD-Link II Serializer and Deserializer
Serial Control Bus AC Timing Specifications (SCL, SDA) - I2C Compliant
(Figure 4)
Over recommended supply and temperature ranges unless otherwise specified.
Symbol
Parameter
Conditions
Min
Typ
Max Units
RECOMMENDED INPUT TIMING REQUIREMENTS (Note 12)
fSCL
tLOW
tHIGH
tHD:STA
SCL Clock Frequency
SCL Low Period
SCL High Period
fSCL = 100 kHz
Hold time for a start or a repeated start
condition
>0
100
kHz
4.7
µs
4.0
µs
4.0
µs
tSU:STA
Set Up time for a start or a repeated
start condition
4.7
µs
tHD:DAT Data Hold Time
tSU:DAT Data Set Up Time
tSU:STO Set Up Time for STOP Condition
tr
SCL & SDA Rise Time
tf
SCL & SDA Fall Time
Cb
Capacitive load for bus
SWITCHING CHARACTERISTICS (Note 11)
0
3.45
µs
250
ns
4.0
µs
1000
ns
300
ns
400
pF
tHD:DAT
tSU:DAT
tf
Data Hold Time
Data Set Up Time
SCL & SDA Fall Time
0
3.45
µs
250
ns
300
ns
FIGURE 4. Serial Control Bus Timing
30164636
Serial Control Bus DC Characteristics (SCL, SDA) - I2C Compliant
Over recommended supply and temperature ranges unless otherwise specified.
Symbol
Parameter
Conditions
Min
Typ
Max
VIH
Input High Level
SDA and SCL
VIL
Input Low Level Voltage SDA and SCL
VHY
Input Hysteresis
SDA and SCL
IOZ
TRI-STATE Output Current PDB = 0V
VOUT = 0V or VDD
IIN
Input Current
SDA or SCL,
Vin = VDDIO or GND
0.7 x
VDDIO
VDDIO
GND
0.3 x
VDDIO
>50
-20
±1
+20
-20
±1
+20
Units
V
V
mV
µA
µA
13
www.national.com