bq2022A
SLUS724E – SEPTEMBER 2006 – REVISED MARCH 2016
NOTE
An 8-bit CRC of the command byte and address bytes is computed by the bq2022A and
read back by the host to confirm that the correct command word and starting address
were received.
If the CRC read by the host is incorrect, a reset pulse must be issued and the entire sequence must be repeated.
If the CRC received by the host is correct, the host issues read time slots and receives data from the bq2022A
starting at the supplied address and continuing until the end of the EPROM Status data field is reached. At that
point, the host receives an 8-bit CRC that is the result of shifting into the CRC generator all of the data bytes
from the initial starting byte through the final factory-programmed byte that contains the 00h value.
This feature is provided because the EPROM status information may change over time making it impossible to
program the data once and include an accompanying CRC that is always valid. Therefore, the READ status
command supplies an 8-bit CRC that is based on (and always is consistent with) the current data stored in the
EPROM status data field.
After the 8-bit CRC is read, the host receives logical 1s from the bq2022A until a reset pulse is issued. The
READ STATUS command sequence can be ended at any point by issuing a reset pulse.
Initialization and SKIP
ROM Command
Sequence
READ MEMORY Command
AAh
Address Low
Byte
Address High
Byte
Read and
Verify
CRC
A0
A7 A8
A15
Read STATUS
Memory Until
End of STATUS
Memory
Read and
Verify CRC
Figure 10. READ STATUS Command
7.5.8 WRITE STATUS Command
The WRITE STATUS command is used to program the EPROM Status data field after the bq2022A has been
issued SKIP ROM command.
The flow chart in Figure 11 illustrates that the host issues the WRITE STATUS command, 55h, followed by the
address low byte and then the address high byte the followed by the byte of data to be programmed.
NOTE
Individual bytes of address and data are transmitted LSB first. An 8-bit CRC of the
command byte, address bytes, and data byte is computed by the bq2022A and read back
by the host to confirm that the correct command word, starting address, and data byte
were received.
If the CRC read by the host is incorrect, a reset pulse must be issued and the entire sequence must be repeated.
If the CRC received by the host is correct, the program command (5Ah) is issued. After the program command is
issued, then the programming voltage, VPP is applied to the DATA pin for period tPROG. Prior to programming, the
first seven bytes of the EPROM STATUS data field appear as logical 1s. For each bit in the data byte provided
by the host that is set to a logical 0, the corresponding bit in the selected byte of the EPROM STATUS data field
is programmed to a logical 0 after the programming pulse has been applied at the byte location. The eighth byte
of the EPROM STATUS byte data field is factory-programmed to contain 00h.