English
Language : 

BQ24171_15 Datasheet, PDF (9/39 Pages) Texas Instruments – bq24171 JEITA-Compliant Stand-Alone, Switched-Mode Li-Ion and Li-Polymer Battery Charger With Integrated MOSFETs and Power Path Selector
www.ti.com
bq24171
SLUSAF2C – FEBRUARY 2011 – REVISED APRIL 2015
Electrical Characteristics (continued)
4.5 V ≤ V(PVCC, AVCC) ≤ 17 V, –40°C < TJ + 125°C, typical values are at TA = 25°C, with respect to AGND (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
MIN
TYP MAX
INPUT OVERVOLTAGE COMPARATOR (ACOV)
VACOV
AC Overvoltage Rising Threshold to turn off
ACFET
OVPSET rising
1.57
1.6 1.63
VACOV_HYS
AC overvoltage falling hysteresis
OVPSET falling
50
tACOV_RISE_DEG
AC Overvoltage Rising Deglitch to turn off
ACFET and Disable Charge
OVPSET rising
1
tACOV_FALL_DEG
AC Overvoltage Falling Deglitch to turn on
ACFET
OVPSET falling
30
INPUT UNDERVOLTAGE COMPARATOR (ACUV)
VACUV
AC Undervoltage Falling Threshold to turn
off ACFET
OVPSET falling
0.487 0.497 0.507
VACUV_HYS
AC Undervoltage Rising Hysteresis
OVPSET rising
100
tACOV_FALL_DEG
AC Undervoltage Falling Deglitch to turn off
ACFET and Disable Charge
OVPSET falling
1
tACOV_RISE_DEG
AC Undervoltage Rising Deglitch to turn on
ACFET
OVPSET rising
30
THERMAL REGULATION
TJ_REG
Junction Temperature Regulation Accuracy ISET > 120 mV, Charging
120
THERMAL SHUTDOWN COMPARATOR
TSHUT
Thermal shutdown rising temperature
Temperature rising
150
TSHUT_HYS
Thermal shutdown hysteresis
Temperature falling
20
tSHUT_RISE_DEG
Thermal shutdown rising deglitch
Temperature rising
100
tSHUT_FALL_DEG
Thermal shutdown falling deglitch
Temperature falling
10
THERMISTOR COMPARATOR
VT1
T1 (0 °C) threshold, Charge suspended
below this temperature.
VTS rising, As Percentage to VVREF
70.2% 70.8% 71.4%
VT1-HYS
Charge back to ICHARGE / 2 and VFB = 2.1 V
above this temperature.
Hysteresis, VTS falling
0.6%
T2 (10 °C) threshold, Charge back to
VT2
ICHARGE / 2 and VFB = 2.1 V below this
VTS rising, As Percentage to VVREF
68.0% 68.6% 69.2%
temperature.
VT2-HYS
Charge back to ICHARGE and VFB = 2.1 V
above this temperature.
Hysteresis, VTS falling
0.8%
T3 (45 °C) threshold, Charge back to
VT3
ICHARGE and VFB = 2.05 V above this
VTS falling, As Percentage to VVREF
55.5% 56.1% 56.7%
temperature.
VT3-HYS
Charge back to ICHARGE and VFB = 2.1 V
below this temperature.
Hysteresis, VTS rising
0.8%
T4 (50 °C) threshold, Charge back to
VT4
ICHARGE and VFB = 2.025 V above this
VTS falling, As Percentage to VVREF
53.2% 53.7% 54.2%
temperature.
VT4-HYS
Charge back to ICHARGE and VFB = 2.05 V
below this temperature.
Hysteresis, VTS rising
0.8%
VT5
T5 (60 °C) threshold, Charge suspended
above this temperature.
VTS falling, As Percentage to VVREF
47.6% 48.1% 48.6%
VT5-HYS
Charge back to ICHARGE and VFB = 2.025 V
below this temperature.
Hysteresis, VTS rising
1.2%
Deglitch time for Temperature Out of Valid
Charge Range Detection
VTS < VT5 or VTS > VT1
400
Deglitch time for Temperature In Valid
Range Detection
VTS > VT5 + VT5_HYS or VTS < VT1 - VT1_HYS
20
Deglitch time for Temperature Detection
above/below T2, T3, T4 threshold
25
Charge Current when VTS between VT1 and
VT2 range
ICHARGE/
2
UNIT
V
mV
µs
ms
V
mV
µs
ms
°C
°C
°C
µs
ms
ms
ms
Copyright © 2011–2015, Texas Instruments Incorporated
Product Folder Links: bq24171
Submit Documentation Feedback
9