TL16C451 Datasheet, PDF (8/23 Pages) Texas Instruments – ASYNCHRONOUS COMMUNICATIONS ELEMENTS | |||
|
◁ |
TL16C451, TL16C452
ASYNCHRONOUS COMMUNICATIONS ELEMENTS
SLLS053C â MAY 1989 â REVISED AUGUST 1999
tcW
tw1
tw2
tw5
tw6
twRST
tsu1
tsu2
tsu3
th1
th2
th3
td3
td4
Cycle time, write (tw6 + td5 + td6)
Pulse duration, clockâ
Pulse duration, clockâ
Pulse duration, write strobe (IOW)â
Pulse duration, read strobe (IOR)â
Pulse duration, reset
Setup time, address (A0 â A2) valid before IOWâ
Setup time, chip select (CSx) valid before IOWâ
Setup time, data (D0 â D7) valid before IOWâ
Hold time, address (A0 â A2) valid after IOWâ
Hold time, chip select (CSx) valid after IOWâ
Hold time, data (D0 â D7) valid before IOWâ
Delay time, write cycle (IOW)â to IOWâ
Delay time, read cycle (IOR)â to IORâ
175
ns
1
50
ns
1
50
ns
2
80
ns
3
80
ns
1000
ns
2, 3
15
ns
2, 3
15
ns
2
15
ns
2, 3
20
ns
2, 3
20
ns
2
15
ns
2
80
ns
3
80
ns
system switching characteristics over recommended ranges of supply voltage and operating
free-air temperature
td5
td6
tdis(R)
PARAMETER
Delay time, data (D0 â D7) valid before read (IOR)â
Delay time, floating data (D0 â D7) valid after read (IOR)â
Read to driver disable, IORâ to BD0â
FIGURE
3
3
3
TEST CONDITIONS
CL = 100 pF
CL = 100 pF
CL = 100 pF
MIN MAX UNIT
60 ns
0
60 ns
60 ns
receiver switching characteristics over recommended ranges of supply voltage and operating
free-air temperature
PARAMETER
td7 Delay time, RCLKâ to sample clockâ
FIGURE
4
TEST CONDITIONS
td8 Delay time, stop (sample clock)â to set interrupt (INTRPT)â
4
td9 Delay time, read RBR/LSR (IOR)â to reset interrupt (INTRPT)â
4
CL = 100 pF
MIN MAX UNIT
100 ns
1
1 RCLK
cycles
140 ns
transmitter switching characteristics over recommended ranges of supply voltage and operating
free-air temperature
PARAMETER
td10 Delay time, initial write THR (IOW)â to transmit start (SOUT)â
FIGURE TEST CONDITIONS
5
td11 Delay time, stop (SOUT) low to interrupt (INTRPT)â
5
td12 Delay time, write THR (IOW)â to reset interrupt (INTRPT) low
5
td13 Delay time, initial write (IOW)â to THRE interrupt (INTRPT)â
5
td14 Delay time, read IIR (IOR)â to reset THRE interrupt (INTRPT) low
5
CL = 100 pF
CL = 100 pF
MIN MAX UNIT
8
24 baudout
cycles
8
8 baudout
cycles
140 ns
16
32 baudout
cycles
140 ns
modem control switching characteristics over recommended ranges of supply voltage and
operating free-air temperature
PARAMETER
td15 Delay time, write MCR (IOW)â to output (RTS, DTS)ââ
FIGURE TEST CONDITIONS
6
CL = 100 pF
MIN MAX UNIT
100 ns
8
⢠POST OFFICE BOX 655303 DALLAS, TEXAS 75265
|
▷ |