English
Language : 

TL16C451 Datasheet, PDF (7/23 Pages) Texas Instruments – ASYNCHRONOUS COMMUNICATIONS ELEMENTS
TL16C451, TL16C452
ASYNCHRONOUS COMMUNICATIONS ELEMENTS
SLLS053C – MAY 1989 – REVISED AUGUST 1999
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)†
Supply voltage range, VCC (see Note 1 ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.5 V to 7 V
Input voltage range at any input, VI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.5 V to 7 V
Output voltage range, VO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.5 V to 7 V
Continuous total power dissipation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1100 mW
Operating free-air temperature range, TA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0 °C to 70 °C
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 65 °C to 150 °C
Case temperature for 10 seconds, TC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260 °C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: All voltage values are with respect to GND.
recommended operating conditions
Supply voltage, VCC
High-level Input voltage, VIH
Low-level Input voltage, VIL
Operating free-air temperature, TA
MIN
4.75
2
– 0.5
0
NOM
5
MAX
5.25
VCC
0.8
70
UNIT
V
V
V
°C
electrical characteristics over recommended ranges of supply voltage and operating free-air
temperature (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN TYP† MAX UNIT
VOH
High-level output voltage
VOL
Low-level output voltage
IOH = – 0.4 mA on DB0 – DB7
IOH = – 2 mA to 4 mA on PD0 – PD7
2.4
IOH = – 0.2 mA on INIT, AFD, STB, and SLIN
IOH = – 0.2 mA on all other outputs
IOL = 4 mA on DB0 – DB7
IOL = 12 mA on PD0 – PD7
IOL = 10 mA on INIT,
AFD, STB, and SLIN (see Note 2)
V
0.4 V
IOL = 2 mA on all other outputs
IIkg
Input leakage current
VCC = 5.25 V,
VI = 0 to 5.25 V,
VSS = 0,
All other terminals floating
VCC = 5.25 V,
VSS = 0,
Ioz
High-impedance output current
VO = 0 to 5.25 V,
Chip selected and in write mode, or chip deselected
± 10 µA
± 20 µA
ICC
Supply current
VCC = 5.25 V,
VSS = 0,
SIN, DSR, RLSD, CTS, and RI at 2 V,
All other inputs at 0.8 V, XTAL1 at 4 MHz,
10 mA
No load on outputs,
Baud rate = 50 kbit/s
† All typical values are at VCC = 5 V, TA = 25 °C.
NOTE 2: INIT, AFD, STB, and SLIN are open-collector output terminals that each have an internal pullup to VCC. This generates a maximum of
2 mA of internal IOL per terminal. In addition to this internal current, each terminal sinks at least 10 mA while maintaining the VOL
specification of 0.4 V maximum.
system timing requirements over recommended ranges of supply voltage and operating free-air
temperature
PARAMETER
tcR
Cycle time, read (tw7 + td8 + td9)
FIGURE
MIN MAX UNIT
175
ns
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265