English
Language : 

AMC7812 Datasheet, PDF (70/92 Pages) Texas Instruments – 12-Bit ANALOG MONITORING AND CONTROL SOLUTION with Multichannel ADC, DACs, and Temperature Sensors
AMC7812
SBAS513D – JANUARY 2011 – REVISED OCTOBER 2012
www.ti.com
Table 22. Status Register (continued)
BIT
NAME
DEFAULT R/W
DESCRIPTION
8 D1-Low-ALR
0
Remote temperature reading of D1when less than the range flag.
R
D1-Low-ALR = '1' when the local temperature is less than the low-bound threshold.
D1-Low-ALR = '0' when the local temperature is not less than the range.
This bit is only checked when D1 is enabled (EN-D1 = '1'); it is ignored when EN-D1 = '0'.
7 D1-High -ALR
0
Remote temperature reading of D1 when greater than the range flag.
R
D1-High-ALR = '1' when the local temperature is greater than the high-bound threshold.
D1-High-ALR = '0' when the local temperature is not greater than the range.
This bit is only checked when D1 is enabled (EN-D1 = '1'); it is ignored when EN-D1 = '0'.
6 D2-Low-ALR
0
Remote temperature reading of D2 when less than the range flag.
R
D2-Low-ALR = '1' when the local temperature is less than the low-bound threshold.
D2-Low-ALR = '0' when the local temperature is not less than the range.
This bit is only checked when D2 is enabled (EN-D2 = '1'); it is ignored when EN-D2 = '0'.
5 D2-High -ALR
0
Remote temperature reading of D2 when greater than the range flag.
R
D2-High-ALR = '1' when the local temperature is greater than the high-bound threshold.
D2-High-ALR = '0' when the local temperature is not greater than the range.
This bit is only checked when D2 is enabled (EN-D2 = '1'); it is ignored when EN-D2 = '0'.
4 D1-FAIL-ALR
0
Remote sensor D1 failure flag.
R
D1-FAIL-ALR = '1' when the sensor is an open-circuit or short-circuit.
D1-FAIL-ALR = '0' when the sensor is in a normal condition.
This bit is only checked when D1 is enabled (EN-D1 = '1'); it is ignored when EN-D1 = '0'.
3 D2-FAIL-ALR
0
Remote sensor D2 failure flag.
R
D2-FAIL-ALR = '1' when the sensor is an open-circuit or short-circuit.
D2-FAIL-ALR = '0' when the sensor is in a normal condition.
This bit is only checked when D2 is enabled (EN-D2 = '1'); it is ignored when EN-D2 = '0'.
2 THERM-ALR
0
Thermal alarm flag. When the die temperature is equal to or greater than +150°C, the bit is
R
set ('1') and the THERM-ALR flag activates. The on-chip temperature sensor (LT) monitors
the die temperature. If LT is disabled, the THERM-ALR bit is always '0'. The hysteresis of
this alarm is 8°C.
1
—
0
R Reserved. Writing to this bit causes no change. Reading this bit returns '0'.
0
—
0
R Reserved. Writing to this bit causes no change. Reading this bit returns '0'.
70
Submit Documentation Feedback
Product Folder Links: AMC7812
Copyright © 2011–2012, Texas Instruments Incorporated