7.5 Electrical Characteristics
TA = 25°C , VDD = 3.3 V, GND = 0 V (unless otherwise noted).
PARAMETER
TEST CONDITIONS
MIN TYP
TDC CHARACTERISTICS
LSB
Resolution
Single shot measurement
55
TACC-2
Accuracy (Mode 2) (1)
CLOCK = 8 MHz
28
Measured time = 100 µs
50
TSTD-2
Standard Deviation (Mode 2)
Measured time = 1 µs
35
OUTPUT CHARACTERISTICS: TRIGG, INTB, DOUT
VOH
Output voltage high
Isource = -2 mA
VOL
Output voltage low
Isink = 2 mA
INPUT CHARACTERISTICS: ENABLE, START, STOP, CLOCK, DIN, CSB,SCLK
Cin
Input capacitance (2)
POWER CONSUMPTION (see Measurement Mode 1 and Measurement Mode 2)
2.31 2.95
0.35
3
Ish
Shutdown current
IQA
Quiescent Current A
IQB
Quiescent Current B
IQC
Quiescent Current C
EN = LOW
EN = HIGH; TDC running
EN = HIGH; TDC OFF, Clock Counter running
EN = HIGH; measurement stopped, SPI
communication only
0.3
1.35
71
87
IQD
Quiescent Current D
TDC OFF, counter stopped, no communication
50
(1) Accuracy is defined as the systematic error in the output signal; the error of the device excluding noise.
(2) Specified by design.
MAX UNIT
ps
ps
ps
ps
V
0.99 V
pF
2 µA
mA
µA
µA
µA
7.6 Timing Requirements
TIMING REQUIREMENTS: START, STOP INPUTS, CLOCK
PWSTART
Pulse width for Start Signal
PWSTOP
Pulse width for Stop Signal
SERIAL INTERFACE TIMING CHARACTERISTICS (VDD = 3.3 V, fSCLK = 20 MHz) (See Figure 1)
fSCLK
SCLK Frequency
t1
SCLK period
t2
SCLK High Time
t3
SCLK Low Time
t4
DIN setup time
t5
DIN hold time
t6
CSB fall to SCLK rise
t7
Last SCLK rising edge to CSB rising edge
t8
Minimum pause time (CSB high)
t9
Clk fall to DOUT bus transition
MIN NOM
10
10
50
16
16
4
4
6
6
40
MAX UNIT
ns
ns
20 MHz
ns
ns
ns
ns
ns
ns
ns
ns
12 ns
7.7 Switching Characteristics
TA = 25°C , VDD = 3.3 V, GND = 0 V (unless otherwise noted).
PARAMETER
TEST CONDITIONS
WAKE UP TIME
TWAKEUP_PERIOD
Time to be ready for
Measurement
LSB within 0.3% of settled value
MIN TYP MAX UNIT
300
µs