English
Language : 

TDC7200_15 Datasheet, PDF (30/50 Pages) Texas Instruments – TDC7200 Time-to-Digital Converter for Time-of-Flight Applications in LIDAR,Magnetostrictive and Flow Meters
TDC7200
SNAS647C – FEBRUARY 2015 – REVISED AUGUST 2015
www.ti.com
8.6.10 CLOCK_CNTR_STOP_MASK_H: CLOCK Counter STOP Mask High Value Register (address = 08h)
[reset = 00h]
Figure 30. CLOCK Counter STOP Mask_H Register
7
6
5
4
3
CLOCK_CNTR_STOP_MASK_H
R/W-0h
R/W-0h
R/W-0h
R/W-0h
R/W-0h
LEGEND: R/W = Read/Write; R = Read only; -n = value after reset
2
R/W-0h
1
R/W-0h
Table 10. CLOCK Counter STOP Mask_H Register Field Descriptions
Bit Field
Type
7-0 CLOCK_CNTR_STOP_MASK_H R/W
Reset
0
Description
CLOCK Counter STOP Mask, upper 8 Bit
0
R/W-0h
8.6.11 CLOCK_CNTR_STOP_MASK_L: CLOCK Counter STOP Mask Low Value Register (address = 09h)
[reset = 00h]
Figure 31. CLOCK Counter STOP Mask_L Register
7
6
5
4
3
CLOCK_CNTR_STOP_MASK_L
R/W-0h
R/W-0h
R/W-0h
R/W-0h
R/W-0h
LEGEND: R/W = Read/Write; R = Read only; -n = value after reset
2
R/W-0h
1
R/W-0h
0
R/W-0h
Table 11. CLOCK Counter STOP Mask_L Register Field Descriptions
Bit Field
Type
7-0 CLOCK_CNTR_STOP_MASK_L R/W
Reset
0
Description
CLOCK Counter STOP Mask, lower 8 Bit
8.6.12 TIME1: Time 1 Register (address: 10h) [reset = 00_0000h]
Figure 32. TIME1 Register
23
22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Parity Bit
Measurement Result: 23 bit integer value (Bit 22: MSB, Bit 0: LSB)
R-0 R-0 R-0 R-0 R-0 R-0 R-0 R-0 R-0 R-0 R-0 R-0 R-0 R-0 R-0 R-0 R-0 R-0 R-0 R-0 R-0 R-0 R-0 R-0
LEGEND: R/W = Read/Write; R = Read only; -n = value after reset
Table 12. TIME1 Register Field Descriptions
Bit
23
22-0
Field
Parity Bit
Measurement Result: 23 bit integer
value (Bit 22: MSB, Bit 0: LSB)
Type
R
R
Reset
0
0
Description
Parity Bit
Measurement Result
30
Submit Documentation Feedback
Product Folder Links: TDC7200