CLOCK Recommendations (continued)
Because the effect of jitter is random, averaging or accumulating time results reduces the effect of the
uncertainty introduced. If the time is measured m times and the result is averaged, then the uncertainty is
reduced to: Clock_Jitter_Uncertainty = (√n) x (θJITTER) / (√m).
For example, if 64 averages are performed in the example above, then the jitter-related uncertainty is reduced to
25 ps RMS.