CD4051B-Q1 Datasheet, PDF (5/18 Pages) Texas Instruments – CMOS ALALOG MULTIPLEXERS/DEMULTIPLEXERS WITH LOGIC-LEVEL CONVERSION | |||
|
◁ |
CD4051BÄQ1, CD4052BÄQ1, CD4053BÄQ1
CMOS ANALOG MULTIPLEXERS/DEMULTIPLEXERS
WITH LOGIC-LEVEL CONVERSION
SCHS354 â AUGUST 2004
logic diagrams (positive logic) (continued)
CD4053B
Aâ 11
Bâ 10
Câ 9
INHâ 6
16 VDD
Logic-Level
Conversion
Binary to
1-of-2
Decoders
With
Inhibit
IN/OUT
cy cx by bx ay ax
3 5 1 2 13 12
VDD
COM OUT/IN
TG
ac or ay
14
TG
COM OUT/IN
TG
bc or by
15
TG
COM OUT/IN
TG
xc or xy
4
TG
8 VSS
7 VEE
â All inputs are protected by standard CMOS protection network.
absolute maximum ratings over operating free-air temperature (unless otherwise noted)â¡
Supply voltage range, V+ to Vâ (voltages referenced to VSS terminal) . . . . . . . . . . . . . . . . . . . . . â0.5 to 20 V
DC input voltage range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . â0.5 V to VDD + 0.5 V
DC input current, any one input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±10 mA
Package thermal impedance, θJA (see Note 1): M package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73°C/W
PW package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108°C/W
Maximum junction temperature, TJ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150°C
Lead temperature (during soldering):
At distance 1/16 ± 1/32 inch (1,59 ± 0,79 mm) from case for 10 s max . . . . . . . . . . . . . . . . . . . . . . . 265°C
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . â65°C to 150°C
Ä Stresses beyond those listed under âabsolute maximum ratingsâ may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under ârecommended operating conditionsâ is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: The package thermal impedance is calculated in accordance with JESD 51-7.
⢠POST OFFICE BOX 655303 DALLAS, TEXAS 75265
5
|
▷ |