English
Language : 

MSP430FG47X Datasheet, PDF (29/91 Pages) Texas Instruments – MIXED SIGNAL MICROCONTROLLER
MSP430FG47x
MIXED SIGNAL MICROCONTROLLER
SLAS580D -- OCTOBER 2008 -- REVISED MARCH 2011
electrical characteristics over recommended operating free-air temperature (unless otherwise
noted) (continued)
outputs -- Ports P1, P2, P3, P4, P5, and P6 (continued)
TYPICAL LOW-LEVEL OUTPUT CURRENT
vs
LOW-LEVEL OUTPUT VOLTAGE
30
VCC = 2.2 V
P1.0
25
TA = --40C
TA = 25C
TA = 85C
20
15
10
5
0
0.0
0.5
1.0
1.5
2.0
2.5
VOL -- Low-Level Output Voltage -- V
Figure 3
TYPICAL LOW-LEVEL OUTPUT CURRENT
vs
LOW-LEVEL OUTPUT VOLTAGE
50
45
VCC = 3 V
P1.0
40
35
TA = --40C
TA = 25C
TA = 85C
30
25
20
15
10
5
0
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5
VOL -- Low-Level Output Voltage -- V
Figure 4
TYPICAL HIGH-LEVEL OUTPUT CURRENT
vs
HIGH-LEVEL OUTPUT VOLTAGE
0.0
VCC = 2.2 V
P1.0
--5.0
--10.0
--15.0
--20.0 TA = 85C
TA = 25C
--25.0
TA = --40C
--30.0
0.0
0.5
1.0
1.5
2.0
2.5
VOH -- High-Level Output Voltage -- V
Figure 5
0.0
--5.0
--10.0
TYPICAL HIGH-LEVEL OUTPUT CURRENT
vs
HIGH-LEVEL OUTPUT VOLTAGE
VCC = 3 V
P1.0
--15.0
--20.0
--25.0
--30.0
--35.0
--40.0
--45.0
TA = 85C
TA = 25C
--50.0
TA = --40C
--55.0
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5
VOH -- High-Level Output Voltage -- V
Figure 6
 POST OFFICE BOX 655303 DALLAS, TEXAS 75265
29