MSP430FG47X Datasheet, PDF (27/91 Pages) Texas Instruments – MIXED SIGNAL MICROCONTROLLER | |||
|
◁ |
MSP430FG47x
MIXED SIGNAL MICROCONTROLLER
SLAS580D -- OCTOBER 2008 -- REVISED MARCH 2011
electrical characteristics over recommended operating free-air temperature (unless otherwise
noted) (continued)
Schmitt-trigger inputs -- Ports P1, P2, P3, P4, P5, and P6, RST/NMI, JTAG (TCK, TMS, TDI/TCLK, TDO/TDI)
PARAMETER
TEST CONDITIONS MIN MAX UNIT
VIT+
VIT--
Vhys
Positive-going input threshold voltage
Negative-going input threshold voltage
Input voltage hysteresis (VIT+ -- VIT--)
VCC = 2.2 V
VCC = 3 V
VCC = 2.2 V
VCC = 3 V
VCC = 2.2 V
VCC = 3 V
1.1 1.55
1.5 1.98
V
0.4 0.9
0.9
1.3
V
0.3
0.5
1.1
1
V
inputs Px.y, TAx
PARAMETER
t(int)
External interrupt timing
TEST CONDITIONS
Port P1, P2: P1.x to P2.x, external trigger signal
for the interrupt flag (see Note 1)
VCC
2.2 V
3V
MIN MAX UNIT
62
50
ns
t(cap)
Timer_A capture timing
TA0, TA1, TA2
2.2 V
62
3V
50
ns
f(TAext)
Timer_A clock frequency externally
applied to pin
TACLK, INCLK: t(H) = t(L)
2.2 V
3V
8
10
MHz
f(TAint)
Timer_A, clock frequency
SMCLK or ACLK signal selected
2.2 V
3V
8
10 MHz
NOTES: 1. The external signal sets the interrupt flag every time the minimum t(int) parameters are met. It may be set even with trigger signals
shorter than t(int).
leakage current -- Ports P1, P2, P3, P4, P5, and P6 (see Note 1)
PARAMETER
TEST CONDITIONS
MIN MAX UNIT
Ilkg(Px.y)
Leakage current
Port Px V(Px.y) (see Note 2)
VCC = 2.2 V/3 V
ï±50 nA
NOTES: 1. The leakage current is measured with VSS or VCC applied to the corresponding pin(s), unless otherwise noted.
2. The port pin must be selected as input.
ï· POST OFFICE BOX 655303 DALLAS, TEXAS 75265
27
|
▷ |