9.6 Register Maps
bq24160, bq24160A, bq24161
bq24161B, bq24163, bq24168
SLUSAO0F – NOVEMBER 2011 – REVISED JULY 2014
9.6.1 Status/Control Register (READ/WRITE)
Memory location: 00, Reset state: 0xxx 0xxx
BIT
B7 (MSB)
B6
B5
B4
B3
B2
B1
B0 (LSB)
NAME
TMR_RST
STAT_2
STAT_1
STAT_0
SUPPLY_SEL
FAULT_2
FAULT_1
FAULT_0
Read/Write FUNCTION
Read/Write Write: TMR_RST function, write “1” to reset the watchdog timer (auto clear)
Read: Always 0
(bq24160/1/3 only)
Read only
Read only
Read only
000- No Valid Source Detected
001- IN Ready (shows preferred source when both connected)
010- USB Ready (shows preferred source when both connected)
011- Charging from IN
100- Charging from USB
101- Charge Done
110- NA
111- Fault
Read/Write 0-IN has precedence when both supplies are connected
1-USB has precedence when both supplies are connected (default 0)
Read only
Read only
Read only
000-Normal
001- Thermal Shutdown
010- Battery Temperature Fault
011- Watchdog Timer Expired (bq24160/1/1B/3 only)
100- Safety Timer Expired (bq24160/1/1B/3 only)
101- IN Supply Fault
110- USB Supply Fault
111- Battery Fault
SUPPLY_SEL Bit (Supply Precedence Selector)
The SUPPLY_SEL bit selects which supply has precedence when both supplies are present. In cases
where both supplies are connected, they must remain isolated from each other which means only one
is allowed to charge the battery. Write a “1” to SUPPLY_SEL to select the USB input to have
precedence. Write a “0” to select the IN input.Note the following behavior when switching the
SUPPLY_SEL bit with both supplies attached:
• The bq2416xx returns to high impedance mode
• The input supply is switched
• The bq2416xx begins a full startup cycle starting with bad adapter detection then proceeding to soft-start
Similarly, if charging from the non-preferred supply when the preferred supply is attached, the
bq2416xx follows the same procedure.
STAT_x and FAULT_x Bits
The STAT_x show the current status of the device and are updated dynamically as the IC changes
state. The FAULT_x bits show faults that have occurred and are only cleared by reading the bits,
assuming the fault no longer exists. If multiple faults occur, the first one is the one that is shown.
9.6.2 Battery/ Supply Status Register (READ/WRITE)
Memory location: 01, Reset state: xxxx 0xxx
BIT
B7 (MSB)
B6
B5
B4
NAME
INSTAT1
INSTAT0
USBSTAT1
USBSTAT0
Read/Write
Read Only
Read Only
Read Only
Read Only
FUNCTION
00-Normal
01-Supply OVP
10-Weak Source Connected (No Charging)
11- VIN<VUVLO
00-Normal
01-Supply OVP
01-Weak Source Connected (No Charging)
11- VUSB<VUVLO