THS1206 Datasheet, PDF (21/41 Pages) Texas Instruments – 12-BIT 6 MSPS, SIMULTANEOUS SAMPLING ANALOG-TO-DIGITAL CONVERTERS
THS1206
12-BIT 6 MSPS, SIMULTANEOUS SAMPLING
ANALOG-TO-DIGITAL CONVERTERS
SLAS217D – MAY 1999 – REVISED APRIL 2000
analog input channel selection (continued)
control register 1 (see Table 8)
–
–
BIT 9
BIT 8
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
–
– RBACK OFFSET BIN/2s
R/W DATA_P DATA_T TRIG1 TRIG0 OVFL/FRST RESET
Table 12. Control Register 1 Bit Functions
BITS
0
RESET
VALUE
0
1
0
2, 3 0,0
4
1
5
1
6
0
7
0
8
0
9
0
NAME
RESET
OVFL
(read only)
FRST
(write only)
TRIG0,
TRIG1
DATA_T
DATA_P
R/W
BIN/2s
OFFSET
RBACK
FUNCTION
Reset
Writing a 1 into this bit resets the device and sets the control register 0 and control register 1 to the reset
values. In addition the FIFO pointer and offset register is reset. After reset, it takes 5 clock cycles until the first
value is converted and written into the FIFO.
Overflow flag (read only)
Bit 1 of control register 1 indicates an overflow in the FIFO.
Bit 1 = 0 → no overflow occurred.
Bit 1 = 1 → an overflow occurred. This bit is reset to 0, after this control register is read from the processor.
FRST: FIFO reset (write only)
By writing a 1 into this bit, the FIFO is reset.
FIFO trigger level
Bit 2 and bit 3 of control register 1 are used to set the trigger level for the FIFO. If the trigger level is reached,
the signal DATA_AV (data available) becomes active according to the settings of DATA_T and DATA_P. This
indicates to the processor that the ADC values can be read. Refer to Table 13.
DATA_AV type
Bit 4 of control register 1 controls whether the DATA_AV signal is a pulse or static (e.g for edge or level
sensitive interrupt inputs). If it is set to 0, the DATA_AV signal is static. If it is set to 1, the DATA_AV signal is a
pulse. Refer to Table 14.
DATA_AV polarity
Bit 5 of control register 1 controls the polarity of DATA_AV. If it is set to 1, DATA_AV is active high. If it is set to 0,
DATA_AV is active low. Refer to Table 14.
R/W, RD/WR selection
Bit 6 of control register 1 controls the function of the inputs RD and WR. When bit 6 in control register 1 is set
to 1, WR becomes a R/W input and RD is disabled. From now on a read is signalled with R/W high and a write
with R/W as a low signal. If bit 6 in control register 1 is set to 0, the input RD becomes a read input and the input
WR becomes a write input.
Complement select
If bit 7 of control register 1 is set to 0, the output value of the ADC is in twos complement. If bit 7 of
control register 1 is set to 1, the output value of the ADC is in binary format. Refer to Table 3 through Table 6.
Offset cancellation mode
Bit 8 = 0 → normal conversion mode
Bit 8 = 1 → offset calibration mode
If a 1 is written into bit 8 of control register 1, the device internally sets the inputs to zero and does a con-
version. The conversion result is stored in an offset register and subtracted from all conversions in order
to reduce the offset error.
Debug mode
Bit 9 = 0 → normal conversion mode
Bit 9 = 1 → enable debug mode
When bit 9 of control register 1 is set to 1, debug mode is enabled. In this mode, the contents of control
register 0 and control register 1 can be read back. The first read after bit 9 is set to 1 contains the value of
control register 0. The second read after bit 9 is set to 1 contains the value of control register 1.