English
Language : 

THS1206 Datasheet, PDF (12/41 Pages) Texas Instruments – 12-BIT 6 MSPS, SIMULTANEOUS SAMPLING ANALOG-TO-DIGITAL CONVERTERS
THS1206
12-BIT 6 MSPS, SIMULTANEOUS SAMPLING
ANALOG-TO-DIGITAL CONVERTERS
SLAS217D – MAY 1999 – REVISED APRIL 2000
continuous conversion mode (continued)
Figure 4 shows the timing of continuous conversion mode when three analog input channels are selected. The
maximum throughput rate per channel is 2 MSPS in this mode. The data flow in the bottom of the figure shows
in which order the converted data is written into the FIFO. The timing of the DATA_AV signal shown here is for
a trigger level set to 3.
Sample N
Channel 1,2,3
Sample N+1
Channel 1,2,3
AIN
tw(CONV_CLKH)
CONV_CLK
td(A)
td(Pipe)
tw(CONV_CLKL)
50%
50%
tc
Data Into
FIFO
Data N–2
Channel 2
Data N–2
Channel 3
Data N–1
Channel 2
td(O)
Data N–1
Channel 2
Data N–1
Channel 3
Sample N+2
Channel 1,2,3
Data N
Channel 1
Data N
Channel 2
Data N+1
Channel 3
DATA_AV,
Trigger Level = 3
td(DATA_AV)
Figure 4. Timing of Continuous Conversion Mode (3-channel operation)
Figure 5 shows the timing of continuous conversion mode when four analog input channels are selected. The
maximum throughput rate per channel is 1.5 MSPS in this mode. The data flow in the bottom of the figure shows
in which order the converted data is written into the FIFO. The timing of the DATA_AV signal shown here is for
a trigger level of 4.
Sample N
Channel 1,2,3,4
AIN
tw(CONV_CLKH)
CONV_CLK
td(A)
50%
td(Pipe)
tw(CONV_CLKL)
50%
tc
Data Into
FIFO
Data N–2
Channel 4
Data N–1 Data N–1
Channel 1 Channel 2
Sample N+1
Channel 1,2,3,4
td(O)
Data N–1 Data N–1
Channel 3 Channel 4
Data N
Channel 1
Sample N+2
Channel 1,2,3,4
Data N
Data N
Channel 2 Channel 3
Data N
Channel 4
td(DATA_AV)
DATA_AV,
Trigger Level = 4
Figure 5. Timing of Continuous Conversion Mode (4-channel operation)
12
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265