English
Language : 

AMC7812SPAPR Datasheet, PDF (10/92 Pages) Texas Instruments – 12-Bit Analog Monitoring and Control Solution with Multichannel ADC, DACs, and Temperature Sensors
AMC7812
SBAS513E – JANUARY 2011 – REVISED SEPTEMBER 2013
I2C-COMPATIBLE TIMING DIAGRAMS
S
Sr
www.ti.com
P
S
SDA
tLOW
tSU, DAT
tHD, DAT
tSU, STA
tHD, STA
tSU, STO
tBUF
SCL
tHD,STA
tHIGH
tR
tF
= Resistor Pull-Up
S = START Condition
Sr = Repeated START Condition
P = STOP Condition
Figure 1. Timing for Standard and Fast Mode Devices on the I2C Bus
TIMING CHARACTERISTICS: SDA and SCL for Standard and Fast Modes(1)
At –40°C to +105°C, AVDD = DVDD = 4.5V to 5.5V, AGND = DGND = 0V, and IOVDD = 2.7V to 5.5V, unless otherwise noted.
STANDARD
MODE
FAST
MODE
fSCL (2)
tLOW
tHIGH
tSU, STA
tHD, STA
PARAMETER
SCL clock frequency
Low period of the SCL clock
High period of the SCL clock
Set-up time for a repeated start condition
Hold time (repeated) start condition. After this
period, the first clock pulse is generated
MIN
MAX
0
100
4.7
—
4.0
—
4.7
—
4.0
—
MIN
MAX UNIT
0
400 kHz
1.3
—
µs
0.6
—
µs
0.6
—
µs
0.6
—
µs
tSU, DAT
tHD, DAT
tSU, STO
tR
tF
tBUF
CB
tSP
Data set-up time
Data hold time: for I2C-bus devices
Set-up time for stop condition
Rise time of both SDA and SCL signals
Fall time of both SDA and SCL signals
Bus free time between a stop and start condition
Capacitive load for each bus line
Pulse width of spike suppressed
250
—
100
0
3.45
0
4.0
—
0.6
—
1000 20 + 0.1CB(3)
—
300 20 + 0.1CB(3)
4.7
—
1.3
—
400
—
NA
NA
0
—
ns
0.9
µs
—
µs
300
ns
300
ns
—
µs
400
pF
50
ns
(1) All values refer to VIHmin and VILmax levels.
(2) An SCL operating frequency of at least 1kHz is recommended to avoid activating the I2C timeout function. See the Timeout Function
section for details.
(3) CB = total capacitance of one bus line in pF.
10
Submit Documentation Feedback
Product Folder Links: AMC7812
Copyright © 2011–2013, Texas Instruments Incorporated