THCV231_16 Datasheet, PDF (24/56 Pages) THine Electronics, Inc. – The THCV231 and THCV236 are designed to support video data transmission between the host and display.
Table 23. Remote side 2-wire serial slave register Read Procedure for 8bit register address
Step
Description
R/W Address
Set slave address of remote side 2-wire serial slave device (Low-order 7bits),
1
and enable this address (High-order 1bit).
W 0x04-0x0B
2 Write 1 or 0 and clear(auto clear) access status register (2WIRE_ACS_END_INT). W
0x02 bit7
Set slave address of access target 2-wire serial slave (choose the value set in
3
W
0x04-0x0B)(Low-order 7bits), and set 0 to 0x20 bit7.
0x20
Set the byte number read from remote side 2-wire serial slave(Max 16byte).
4
(Byte number = register value + 1)
W
0x22
5 Set the start address of remote side 2-wire serial slave register to read.
W
0x24
Write 1 to RD_START_8B. (Start read access to remote side 2-wire serial slave
6
W
register)
0x26 (*1)
2-wire serial slave of Sub-Link Master perform clock stretching until Sub-Link Slave
7
register access is completed. When read access is completed, SCL is released and -
-
(*2)
read data is stored in Sub-Link Master register (Address 0x10-0x1F).
When read access is completed, read data is stored in Sub-Link Master register
7
(Address 0x10-0x1F) and 2WIRE_ACS_END_INT register value become 1 and -
-
(*3)
interrupt occurs (INT=H → L).
8 If read access was normally ended, read value should be “0x1”.
R
0x02
9 HOST MPU read data stored in Sub-Link Master register.
R 0x10-0x1F
10 Repeat from step2 to step10 if needed.
-
-
*1 It’s Prohibit that HOST MPU start access to Sub-Link Slave or remote 2-wire serial slave before the previous access to
Sub-Link Slave or remote side 2-wire serial slave is completed.
*2 When 2WIRE_MODE = 00 (Clock Stretching Mode)
*3 When 2WIRE_MODE = 01 (No Clock Stretching Mode)
THCV231_THCV236_Rev.2.30_E