Table 20. Sub-Link slave register Read Procedure
Step
Description
R/W Address
1 Write 1 or 0 and clear(auto clear) access status register (2WIRE_ACS_END_INT). W
0x02 bit7
Set Device ID of Sub-Link Master device.
2
W
(Value corresponding to AIN1 and AIN0 setting. e.g. [AIN1,AIN0]=[0,0] → 7’h0B)
0x20
Set the byte number read from Sub-Link Slave(Max 16byte).
3
(Byte number = register value + 1)
W
0x22
4 Set the start address of Sub-Link Slave register to read.
W
0x24
5 Write 1 to RD_START_8B. (Start read access to Sub-Link Slave register)
W
0x26 (*1)
2-wire serial slave of Sub-Link Master perform clock stretching until Sub-Link Slave
6
register access is completed. When read access is completed, SCL is released and -
-
(*2)
read data is stored in Sub-Link Master register (Address 0x10-0x1F).
When read access is completed, read data is stored in Sub-Link Master register
6
(Address 0x10-0x1F) and 2WIRE_ACS_END_INT register value become 1 and -
-
(*3)
interrupt occurs (INT=H → L).
7 If read access was normally ended, read value should be “0x1”.
R
0x02
8 HOST MPU read data stored in Sub-Link Master register.
R
0x10-0x1F
*1 It’s Prohibit that HOST MPU start access to Sub-Link Slave or remote 2-wire serial slave before the previous access to
Sub-Link Slave or remote side 2-wire serial slave is completed.
*2 When 2WIRE_MODE = 00 (Clock Stretching Mode)
*3 When 2WIRE_MODE = 01 (No Clock Stretching Mode)
THCV231_THCV236_Rev.2.30_E