English
Language : 

CGA3E2X7R2A103K080AA Datasheet, PDF (9/31 Pages) TDK Electronics – SPECIFICATION
(continued)
No.
Item
Performance
15 Moisture External
No mechanical damage.
Resistance appearance
(Steady
State)
Capacitance
Characteristics
Change from the
value before test
Capacitance drift
Class1
C0G
within ± 7.5% or
± 0.75pF,
whichever larger.
X5R
Class2
X7R
X7S
X7T
± 12.5 %
Q
(Class1)
D.F.
(Class2)
Capacitance
Q
30pF and over
350 min.
10pF and over
under 30pF
275+5/2×C min.
Under 10pF
200+10×C min.
C : Rated capacitance (pF)
Characteristics
200% of initial spec. max.
Insulation
Resistance
1,000MΩ or 50MΩ·μF min.
(As for the capacitors of rated
voltage 16V DC and item
below, 1,000MΩ or 10MΩ·μF
min.,)
whichever smaller.
16 Moisture External
No mechanical damage.
Resistance appearance
Capacitance
Characteristics
Change from the
value before test
Capacitance drift
Class1
C0G
within ± 7.5% or
± 0.75pF,
whichever larger.
X5R
Class2
X7R
X7S
X7T
± 12.5 %
Q
(Class1)
D.F.
(Class2)
Capacitance
Q
30pF and over 200 and over
Under 30pF 100+10/3×C min.
C : Rated capacitance (pF)
Characteristics
200% of initial spec. max.
Insulation
Resistance
500MΩ or 25MΩ·μF min.
(As for the capacitors of rated
voltage 16V DC and item
below, 500MΩ or 5MΩ·μF min.,)
whichever smaller.
Test or inspection method
Reflow solder the capacitors on a
P.C.Board shown in Appendix 1a or
Appendix 1b before testing.
Leave at temperature 40±2°C, 90 to
95%RH for 500 +24,0h.
Leave the capacitors in ambient
condition for 6 to 24h (Class1) or
24±2h (Class2) before measurement.
Reflow solder the capacitors on a
P.C.Board shown in Appendix 1a or
Appendix 1b before testing.
Apply the rated voltage at temperature
85°C and 85%RH for 1000 +24,0h.
Charge/discharge current shall not
exceed 50mA.
Leave the capacitors in ambient
condition for 6 to 24h (Class1) or
24±2h (Class2) before measurement.
Voltage conditioning (only for class 2)
Voltage treat the capacitors under
testing temperature and voltage for 1
hour.
Leave the capacitors in ambient
condition for 24±2h before
measurement.
Use this measurement for initial value.
—8—