CGA3E2X7R2A103K080AA Datasheet, PDF (9/31 Pages) TDK Electronics – SPECIFICATION | |||
|
◁ |
(continued)
No.
Item
Performance
15 Moisture External
No mechanical damage.
Resistance appearance
(Steady
State)
Capacitance
Characteristics
Change from the
value before test
Capacitance drift
Class1
C0G
within ± 7.5% or
± 0.75pF,
whichever larger.
X5R
Class2
X7R
X7S
X7T
± 12.5 %
Q
(Class1)
D.F.
(Class2)
Capacitance
Q
30pF and over
350 min.
10pF and over
under 30pF
275+5/2ÃC min.
Under 10pF
200+10ÃC min.
C : Rated capacitance (pF)
Characteristics
200% of initial spec. max.
Insulation
Resistance
1,000M⦠or 50Mâ¦Â·Î¼F min.
(As for the capacitors of rated
voltage 16V DC and item
below, 1,000M⦠or 10Mâ¦Â·Î¼F
min.,)
whichever smaller.
16 Moisture External
No mechanical damage.
Resistance appearance
Capacitance
Characteristics
Change from the
value before test
Capacitance drift
Class1
C0G
within ± 7.5% or
± 0.75pF,
whichever larger.
X5R
Class2
X7R
X7S
X7T
± 12.5 %
Q
(Class1)
D.F.
(Class2)
Capacitance
Q
30pF and over 200 and over
Under 30pF 100+10/3ÃC min.
C : Rated capacitance (pF)
Characteristics
200% of initial spec. max.
Insulation
Resistance
500M⦠or 25Mâ¦Â·Î¼F min.
(As for the capacitors of rated
voltage 16V DC and item
below, 500M⦠or 5Mâ¦Â·Î¼F min.,)
whichever smaller.
Test or inspection method
Reflow solder the capacitors on a
P.C.Board shown in Appendix 1a or
Appendix 1b before testing.
Leave at temperature 40±2°C, 90 to
95%RH for 500 +24,0h.
Leave the capacitors in ambient
condition for 6 to 24h (Class1) or
24±2h (Class2) before measurement.
Reflow solder the capacitors on a
P.C.Board shown in Appendix 1a or
Appendix 1b before testing.
Apply the rated voltage at temperature
85°C and 85%RH for 1000 +24,0h.
Charge/discharge current shall not
exceed 50mA.
Leave the capacitors in ambient
condition for 6 to 24h (Class1) or
24±2h (Class2) before measurement.
Voltage conditioning (only for class 2)
Voltage treat the capacitors under
testing temperature and voltage for 1
hour.
Leave the capacitors in ambient
condition for 24±2h before
measurement.
Use this measurement for initial value.
â8â
|
▷ |