English
Language : 

COM20020I_06 Datasheet, PDF (34/65 Pages) SMSC Corporation – 5Mbps ARCNET (ANSI 878.1) Controller with 2K x 8 On-Chip RAM
5Mbps ARCNET (ANSI 878.1) Controller with 2K x 8 On-Chip RAM
Table 12 - Setup 2 Register
BIT
BIT NAME
SYMBOL
DESCRIPTION
7 Read Bus Timing RBUSTMG This bit is used to Disable/Enable the High Speed CPU
Select
Read function for High Speed CPU bus support.
RBUSTMG=0: Disable (Default), RBUSTMG=1: Enable. It
does not influence write operation. High speed CPU Read
operation is only for non-multiplexed bus.
6 Reserved
This bit is undefined.
5,4 Clock Multiplier
CKUP1, 0
Higher frequency clocks are generated from the 20 MHz
crystal through the selection of these two bits as shown.
This clock multiplier is powered-down on default. After
changing the CKUP1 and CKUP0 bits, the ARCNET core
operation is stopped and the internal PLL in the clock
multiplier is awakened and it starts to generate the 40 MHz.
The lock out time of the internal PLL is 8μSec typically.
After 1 mS it is necessary to write command data '18H' to
command register for re-starting the ARCNET core
operation. EF bit must be ‘1’ if the data rate is over 5Mbps.
CAUTION: Changing the CKUP1 and CKUP0 bits must be
one time or less after releasing a hardware reset.
CKUP1 CKUP0 Clock Frequency (Data Rate)
0
0
20 MHz (Up to 2.5Mbps) Default
0
1
40 MHz (Up to 5Mbps)
1
0
Reserved
1
1
Reserved
Note: After changing the CKUP1 or CKUP0 bits, it is
necessary to write a command data '18H' to the command
register. Because after changing the CKUP [1, 0] bits, the
internal operation is stopped temporarily. The writing of the
command is to start the operation.
These initializing steps are shown below.
1) Hardware reset (Power ON)
2) Change CKUP[1, 0] bit
3) Wait 1mSec (wait until stable oscillation)
4) Write command '18H' (start internal operation)
5) Start initializing routine (Execute existing software)
3 Enhanced
Functions
EF
This bit is used to enable the new enhanced functions in the
COM20020I. EF = 0: Disable (Default), EF = 1: Enable. If
EF = 0, the timing and function is the same as in the
COM20020I, Revision B. See appendix “A”. EF bit must
be ‘1’ if the data rate is over 5Mbps.
EF bit should be ‘1’ for new design customers.
EF bit should be ‘0’ for replacement customers.
2 No Synchronous
NOSYNC
This bit is used to enable the SYNC command during
initialization. NOSYNC= 0, Enable (Default) The line must
be idle for the RAM initialization sequence to be written.
NOSYNC= 1, Disable:) The line does not have to be idle for
the RAM initialization sequence to be written. See appendix
“A”.
Revision 12-06-06
34
DATASHEET
SMSC COM20020I 3.3V