Table 6. SKY65362-11 Transmit Mode Electrical Specifications (2 of 2) (Note 1)
(VCC = +5.0 V, TA = +25 C, as Measured on the SKY65362-11 Evaluation Board [De-Embedded to Device], All Unused Ports Terminated
with 50 Ω, Input Port = PA_IN, Outport Port = ANT1, Unless Otherwise Noted)
Parameter
Symbol
Test Condition
Min
Typical
Max
Units
Forward power detect
PFWD
Up to VSWR = 2.5:1
0.35
1.2
V
Reverse power detect
PREV
Up to VSWR = 2.5:1
0.35
1.2
V
Power detector accuracy
PDET_ACC
VSWR = 2.5:1 (Note 3)
±1
dB
Current alarm trigger output
IALARM
Low if ICC < 800 mA,
High if ICC > 800 mA (Note 4)
800
mA
Stability
STAB
CW, POUT = +30.5 dBm into
50 Ω, 0.1 to 20 GHz,
load VSWR = 6:1 (Note 3)
All non-harmonically related outputs < –43 dBm
Ruggedness
RUG
CW, POUT = +30.5 dBm into
50 Ω load, VSWR = 10:1 (Note 3)
No permanent damage
Note 1: Performance is guaranteed only under the conditions listed in this table.
Note 2: Harmonics above 5th are not production tested. Guaranteed by characterization.
Note 3: Not production tested. Guaranteed by characterization.
Note 4: Current Alarm trigger point is adjustable by external components R2, R3, R4, R5 in Figure 3. Contact Sales support for further information.
Table 7. SKY65362-11 Diversity Antenna Electrical Specifications (Note 1)
(VCC = +5.0 V, TA = +25 C, f = 900 MHz to 930 MHz, as Measured on the SKY65362-11 Evaluation Board [De-Embedded to Device], All
Unused Ports Terminated with 50 Ω, Unless Otherwise Noted)
Parameter
Symbol
Test Condition
Min
Typical
Max
Units
Isolation between ANT1 and ANT2 ports
ISOL_ANT1/2
–20
dB
ANT1 to ANT2 switching time, transmit mode tANT1-ANT2_TX (Note 2)
1
μs
ANT1 to ANT2 switching time, receive mode tANT1-ANT2_RX (Note 2)
1
μs
Note 1: Performance is guaranteed only under the conditions listed in this table.
Note 2: Not production tested. Guaranteed by characterization.
Table 8. SKY65362-11 Electrical Specifications: Control Logic Characteristics (Note 1)
(TA = +25 C, as Measured on the SKY65362-11 Evaluation Board [De-Embedded to Device], Unless Otherwise Noted)
Parameter
Symbol
Test Condition
Min
Typical
Max
Control voltage:
High
Low
VIH
(Note 2)
1.6
3.6
VIL
0
0.3
Input current:
High
IIH
(Note 2)
1
Low
IIL
1
Current alarm output voltage
VOH
VCC = 5 V
3.3
Note 1: Performance is guaranteed only under the conditions listed in this table.
Note 2: Not production tested. Guaranteed by characterization.
Units
V
V
μA
μA
V
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
6
January 9, 2015 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 202886B