English
Language : 

SKY65362-11 Datasheet, PDF (4/13 Pages) Skyworks Solutions Inc. – 900 to 930 MHz High-Power RF Front-End Module
DATA SHEET • SKY65362-11: HIGH-POWER RF FEM
Table 4. SKY65362-11 DC Electrical Specifications (Note 1)
(VCC = +5.0 V, TA = +25 C, as Measured on the SKY65362-11 Evaluation Board [De-Embedded to Device], Unless Otherwise Noted)
Parameter
Symbol
Test Condition
Min
Typical
Max
Units
Total supply current, transmit mode
ICC_TX30
ICC_TX27
ICC_TX24
POUT = +30.5 dBm
(Note 2)
POUT = +27 dBm
POUT = +24 dBm
515
mA
300
mA
230
mA
Quiescent current, transmit mode
ICQ_TX
No RF
85
mA
Total supply current, receive mode
ICC_RX
6
mA
Total supply current, receive bypass mode ICC_RXBYP
820
μA
Sleep supply current
ICC_OFF
No RF
0.05
1.00
μA
Note 1: Performance is guaranteed only under the conditions listed in this table.
Note 2: Typical current listed into VSWR = 1:1. ICC = 700 mA into VSWR = 2.5:1 guaranteed by characterization.
Table 5. SKY65362-11 Receive Mode Electrical Specifications (Note 1)
(VCC = +5.0 V, TA = +25 C, as Measured on the SKY65362-11 Evaluation Board [De-Embedded to Device], All Unused Ports Terminated
with 50 Ω, Input Port = ANT1, Output Port = RX, Unless Otherwise Noted)
Parameter
Symbol
Test Condition
Min
Typical
Max
Units
Frequency range
f
900
930
MHz
Gain
S21_RX
900 to 930 MHz
16
dB
Noise figure
NF
900 to 930 MHz
2.5
dB
Third order input intercept point
IIP3
900 to 930 MHz,
–20 dBm/tone, 200 kHz tone
separation
–5
–2
dBm
1 dB Input compression point
IP1dB
900 to 930 MHz
–15
–12
dBm
Antenna port return loss
S11_RX
900 to 930 MHz, into
50 Ω, ANT1 or ANT2 port
–12
–6
dB
Receive port return loss in receive or receive
bypass mode
S22_RX
ANT1 terminated in 50 Ω
–12
–6
dB
Turn-on/off time
tON_RX,
tOFF_RX
Receive or receive bypass to
“off,” “off” to receive or
receive bypass, from 50% of
CTX edge to 10% of final RF
output power (Note 2)
11
μs
Gain in receive bypass mode
S21_RXBYP
–4
–3
dB
1 dB Input compression point in receive
bypass mode
IP1dB_RXBYP
+10
dBm
Note 1: Performance is guaranteed only under the conditions listed in this table.
Note 2: Not production tested. Guaranteed by characterization.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
4
January 9, 2015 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 202886B