English
Language : 

SKY65362-11 Datasheet, PDF (3/13 Pages) Skyworks Solutions Inc. – 900 to 930 MHz High-Power RF Front-End Module
DATA SHEET • SKY65362-11: HIGH-POWER RF FEM
Electrical and Mechanical Specifications
The absolute maximum ratings of the SKY65362-11 are provided
in Table 2. The recommended operating conditions are specified
in Table 3.
Electrical specifications are provided in Tables 4 through 8. The
state of the SKY65362-11 is determined by the logic provided in
Table 9.
Table 2. SKY65362-11 Absolute Maximum Ratings (Note 1)
Parameter
Symbol
Minimum
Maximum
Units
Supply voltage (no RF)
VCC
–0.3
+6.0
V
Control pin (CSD, CPS, CTX, IALARM, and ANT_SEL) voltage
–0.3
VCC (VCC < 5 V)
V
Operating temperature
TA
–40
+85
C
Storage temperature
TSTG
–40
+125
C
Transmit input power
PIN_TX_MAX
+10
dBm
Receive RF input power @ ANT1 or ANT2 ports
PIN_RX_MAX
+10
dBm
Voltage Standing Wave Ratio @ ANT1 or ANT2 ports
VSWR
10:1
–
Electrostatic discharge:
ESD
Human Body Model (HBM), Class 1C
1000
V
Note 1: Exposure to maximum rating conditions for extended periods may reduce device reliability. There is no damage to device with only one parameter set at the limit and all other
parameters set at or below their nominal value. Exceeding any of the limits listed here may result in permanent damage to the device.
CAUTION: Although this device is designed to be as robust as possible, electrostatic discharge (ESD) can damage this device. This device
must be protected at all times from ESD. Static charges may easily produce potentials of several kilovolts on the human body
or equipment, which can discharge without detection. Industry-standard ESD precautions should be used at all times.
Table 3. SKY65362-11 Recommended Operating Conditions
Parameter
Symbol
Minimum
Typical
Maximum
Units
Supply voltage
VCC
4.75
5.00
5.25
V
Operating temperature
TA
–40
+25
+85
C
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
202886B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • January 9, 2015
3