English
Language : 

SI5010 Datasheet, PDF (5/20 Pages) List of Unclassifed Manufacturers – OC-12/3, STM-4/1 SONET/SDH CLOCK AND DATA RECOVERY IC
Si5010
2. Electrical Specifications
Table 1. Recommended Operating Conditions
Parameter
Symbol
Test Condition
Min1 Typ Max1 Unit
Ambient Temperature
TA
Si5010 Supply Voltage2
VDD
–40
25
85
°C
2.375 2.5 2.625
V
Notes:
1. All minimum and maximum specifications are guaranteed and apply across the recommended operating conditions.
Typical values apply at nominal supply voltages and an operating temperature of 25 °C unless otherwise stated.
2. The Si5010 specifications are guaranteed when using the recommended application circuit (including component
tolerance) shown in "3. Typical Application Schematic" on page 9.
V
SIGNAL +
Differential VICM, VOCM
I/Os SIGNAL –
VIS
Single Ended Voltage
(SIGNAL+) – (SIGNAL–)
Differential
Voltage Swing
VID,VOD
Differential Peak-to-Peak Voltage
t
Figure 1. Differential Voltage Measurement (DIN, REFCLK, DOUT, CLKOUT)
t C-D
DOUT
CLKOUT
Figure 2. Differential Clock to Data Timing
DOUT,
CLKOUT
80%
20%
tF
tR
Figure 3. Differential DOUT and CLKOUT Rise/Fall Times
Rev. 1.3
5