Skew measurement
point
0.000 V
High Duty Cycle %
TPeriod
Si53112-A03A
Low Duty Cycle %
Figure 6. Differential (CLOCK–CLOCK) Measurement Points (Tperiod, Duty Cycle, Jitter)
3.2. Termination of Differential Outputs
All differential outputs are to be tested into an 85  differential impedance transmission line. All output termination
resistors are fully integrated into the Si53119-A03A, no external components are required. Contact Silicon Labs
Support if 100  differential impedance support is needed.
Clock
Zo = 85 , 10" Trace
Receiver
2 pF
2 pF
Clock #
Zo = 85 , 10" Trace
Figure 7. 0.7 V Configuration Test Load Board Termination for NMOS Push-Pull