SI8220 Datasheet, PDF (10/31 Pages) Silicon Laboratories – 0.5 AND 2.5 AMP ISODRIVERS WITH OPTO INPUT (2.5, 3.75, AND 5.0 KVRMS)
Si8220/21
Table 4. IEC 60664-1 (VDE 0844 Part 5) Ratings
Parameter
Basic Isolation Group
Installation Classification
Test Conditions
Material Group
Rated Mains Voltages < 150 VRMS
Rated Mains Voltages < 300 VRMS
Rated Mains Voltages < 400 VRMS
Rated Mains Voltages < 600 VRMS
Specification
NB SOIC8
WB SOIC 16
I
I
I-IV
I-IV
I-III
I-IV
I-II
I-III
I-II
I-III
Table 5. IEC 60747-5-5 Insulation Characteristics for Si822xxC*
Parameter
Symbol
Test Condition
Characteristic
WB
SOIC-16
NB SOIC-8
Unit
Maximum Working Insulation
Voltage
Input to Output Test Voltage
VIORM
VPR
Method b1
(VIORM x 1.875 = VPR, 100%
Production Test, tm = 1 sec,
Partial Discharge < 5 pC)
891
1671
560
V peak
1050
V peak
Highest Allowable Overvoltage
(Transient Overvoltage,
VTR
tTR = 60 sec)
Pollution Degree
(DIN VDE 0110, Table 1)
6000
2
4000 V peak
2
Insulation Resistance at TS,
VIO = 500 V
RS
>109
>109

*Note: This isolator is suitable for basic electrical isolation only within the safety limit data. Maintenance of the safety data is