S-8241ABKMC-GBKT2G Datasheet, PDF (7/39 Pages) Seiko Instruments Inc – BATTERY PROTECTION IC FOR 1-CELL PACK
Rev.9.1_00
BATTERY PROTECTION IC FOR 1-CELL PACK
S-8241 Series
Table 3
Delay time
combination
(1)
Overcharge detection
delay time
[tCU]
1.0 s
Overdischarge detection
delay time
[tDL]
125 ms
Overcurrent 1 detection
delay time
[tlOV1]
8 ms
(2)
0.125 s
31 ms
16 ms
(3)
0.25 s
125 ms
8 ms
(4)
2.0 s
125 ms
8 ms
(5)
0.25 s
31 ms
16 ms
(6)
1.0 s
125 ms
16 ms
(7)
0.5 s
125 ms
8 ms
Remark The delay times can be changed within the range listed Table 4. For details, please contact our sales office.
Table 4
Delay time
Symbol
Selection range
Overcharge detection delay time
tCU
0.25 s 0.5 s
1.0 s
2.0 s
Overdischarge detection delay time tDL
31 ms 62.5 ms 125 ms
⎯
Overcurrent 1 detection delay time tlOV1
4 ms
8 ms 16 ms
⎯
Remark The value surrounded by bold lines is the delay time of the standard products.
Remarks
Select a value from the left.
Select a value from the left.
Select a value from the left.