English
Language : 

S-8241ABKMC-GBKT2G Datasheet, PDF (1/39 Pages) Seiko Instruments Inc – BATTERY PROTECTION IC FOR 1-CELL PACK
S-8241 Series
www.sii-ic.com
© Seiko Instruments Inc., 1999-2012
BATTERY PROTECTION IC
FOR 1-CELL PACK
Rev.9.1_00
The S-8241 Series is a series of lithium ion/lithium polymer rechargeable battery protection ICs incorporating high-accuracy
voltage detection circuits and delay circuits.
These ICs are suitable for protection of 1-cell lithium ion/lithium polymer battery packs from overcharge, overdischarge and
overcurrent.
„ Features
(1) Internal high-accuracy voltage detection circuit
• Overcharge detection voltage: 3.9 V to 4.4 V (5 mV-step)
• Overcharge release voltage:
Accuracy of ±25 mV (+25°C) and ± 30 mV (−5 to +55°C)
3.8 V to 4.4 V*1 Accuracy of ±50 mV
• Overdischarge detection voltage: 2.0 V to 3.0 V (100 mV-step) Accuracy of ±80 mV
• Overdischarge release voltage: 2.0 V to 3.4 V*2 Accuracy of ±100 mV
• Overcurrent 1 detection voltage: 0.05 V to 0.32 V (5 mV-step) Accuracy of ±20 mV
• Overcurrent 2 detection voltage: 0.5 V (fixed) Accuracy of ±100 mV
(2) A high voltage withstand device is used for charger connection pins
(VM and CO pins: Absolute maximum rating = 26 V)
(3) Delay times (overcharge: tCU; overdischarge: tDL; overcurrent 1: tlOV1; overcurrent 2: tlOV2) are generated
by an internal circuit. (External capacitors are unnecessary.) Accuracy of ±30%
(4) Internal three-step overcurrent detection circuit (overcurrent 1, overcurrent 2, and load short-circuiting)
(5) Either the 0 V battery charging function or 0 V battery charge inhibiting function can be selected.
(6) Products with and without a power-down function can be selected.
(7) Charger detection function and abnormal charge current detection function
• The overdischarge hysteresis is released by detecting a negative VM pin voltage (typ. −1.3 V) (Charger detection
function).
• If the output voltage at DO pin is high and the VM pin voltage becomes equal to or lower than the charger detection
voltage (typ. −1.3 V), the output voltage at CO pin goes low (Abnormal charge current detection function).
(8) Low current consumption
• Operation:
3.0 μA typ. 5.0 μA max.
• Power-down mode: 0.1 μA max.
(9) Wide operation temperature range: −40°C to +85°C
(10) Lead-free, Sn 100%, halogen-free*3
*1. Overcharge release voltage = Overcharge detection voltage - Overcharge hysteresis
The overcharge hysteresis can be selected in the range 0.0 V, or 0.1 V to 0.4 V in 50 mV steps. (However, selection
“Overcharge release voltage<3.8 V” is enabled.)
*2. Overdischarge release voltage = Overdischarge detection voltage + Overdischarge hysteresis
The overdischarge hysteresis can be selected in the range 0.0 V to 0.7 V in 100 mV steps. (However, selection
“Overdischarge release voltage>3.4 V” is enabled.)
*3. Refer to “„ Product Name Structure” for details.
„ Applications
• Lithium-ion rechargeable battery pack
• Lithium- polymer rechargeable battery pack
„ Packages
• SOT-23-5
• SNT-6A
Seiko Instruments Inc.
1