7. 0 V battery charge starting charger voltage and 0 V battery charge inhibition battery voltage (Test
circuit 7)
One of the 0 V battery charge starting charger voltage and 0 V battery charge inhibition battery voltage is
applied to each product according to the 0V battery charging function.
Starting condition is V1 = V2 = V3 = V4 = 0 V for a product in which 0 V battery charging is available.
The COP pin voltage should be lower than V0CHA max.−1 V when the VMP pin voltage VMP = V0CHA max.
Starting condition is V1 = V2 = V3 = V4 = V0INH for a product in which 0 V battery charging is inhibited.
The COP pin voltage should be higher than VMP−1 V when the VMP pin voltage VMP = 24 V.
8. Internal resistance (Test circuit 8)
The resistance between VDD and VMP is RVDM and is calculated by the equation RVDM = VDD / IVDM where
IVDM is a VMP pin current after VMP is changed to VSS from the starting condition V1 = V2 = V3 = V4 = 3.5 V
and VMP = VDD.
The resistance between VSS and VMP is RVSM and is calculated by the equation RVSM = VDD / IVSM where
IVSM is a VMP pin current at the condition V1 = V2 = V3 = V4 = 1.8 V and VMP = VDD.
9. Pin current for CTL2 to CTL4, COP, DOP, VBATOUT (Test circuit 9)
Starting condition is V1 = V2 = V3 = V4 = 3.5 V.
Pin current for CTL2 at “High” is ICTL2H and is obtained by setting VCTL2 = VOUT.
Pin current for CTL2 at “Low” is ICTL2L and is obtained by setting VCTL2 = VSS.
Pin current for CTL3 and CTL4 can be obtained in the same manner as in the CTL2.
Pin current for COP at “High” is ICOH and is obtained by setting V1 = V2 = V3 = V4 = 6 V, VMP = VDD, and
VCOP = VDD. And pin current for COP at “Low” is ICOL and is obtained by setting V1 = V2 = V3 = V4 = 3.5 V,
VMP = VDD, and VCOP = 0.5 V.
Pin current for DOP at “Low” is IDOL and is obtained by setting V1 = V2 = V3 = V4 = 3.5 V, VMP = VDD, and
VDOP = 0.5 V. And pin current for COP at “High” is ICOH and is obtained by setting V1 = V2 = V3 =V4 = 3.5
V, VMP = VDD−1 V, and VDOP = VDD−0.5 V.
Pin current for VBATOUT at “High” is IVBATH and is obtained by setting CTL3 and CTL4 are open and
VBATOUT = VOFF3−0.5 V. And pin current for VBATOUT at “Low” is IVBATL and is obtained by setting VBATOUT
= VOFF3+0.5 V.
V1
V2
V3
V4
A
1 VDD
2 DOP
3 COP
4 VMP
5 VC1
6 VC2
7 VC3
8 VSS
VREG 16
CTL1 15
CTL2 14
CTL3 13
CTL4 12
VBATOUT 11
CCT 10
CDT 9
1 VDD
VREG 16
2 DOP
CTL1 15
3 COP
4 VMP
CTL2 14
CTL3 13
5 VC1
CTL4 12
6 VC2 VBATOUT 11
V
7 VC3
CCT 10
8 VSS
CDT 9
Test circuit 1
C1=1 μF
C1=1 μF IOUT
Test circuit 2
14