English
Language : 

SDA9280 Datasheet, PDF (30/43 Pages) Siemens Semiconductor Group – ICs for Consumer Electronics
SDA 9280 B22
Subaddress 0BH: Black Level Coding
Bit
Name Function
D6 ... D0 BLACK
Coding of inserted black level (Y-channel), computation
see chapter ‘Insertion Facilities’:
0000000: 0
0000001: 1
:
:
1111111: 127
D7
No function assigned. Assign binary value: 0
Subaddress 0CH: Background Color/Y Signal
Bit
Name Function
D3 ... D0 COLBY Background color (luminance):4 MSBs
D7 ... D4 COLFY Color of inserted pattern (luminance):4 MSBs
Subaddress 0DH: Background Color/B-Y Signal
Bit
Name Function
D3 ... D0 COLBU Background color (B-Y):4 MSBs
D7 ... D4 COLFU Color of inserted pattern (B-Y):4 MSBs
Subaddress 0EH: Background Color/R-Y Signal
Bit
Name Function
D3 ... D0 COLBV Background color (R-Y):4 MSBs
D7 ... D4 COLFV Color of inserted pattern (R-Y):4 MSBs
Semiconductor Group
30
1998-02-01