English
Language : 

BU92747XXX Datasheet, PDF (33/46 Pages) Rohm – IrDA Controller LSI built-in Ir remote control
BD92747XXX
Datasheet
Address 22h (Read/Write)
Description
D7-D0
(Out10)
Output data
Initial
value
00h Output data of Out10
Operation
Address 23h (Read/Write)
Description
D7-D0
(Out11)
Output data
Initial
value
00h Output data of Out11
Operation
Address 24h (Read/Write)
Description
D7-D0
(Out12)
Output data
Initial
value
00h Output data of Out12
Operation
Address 25h (Read/Write)
Description
D7-D0
(Out13)
Output data
Initial
value
00h Output data of Out13
Operation
Address 26h (Read/Write)
Description
D7-D0
(Out14)
Output data
Initial
value
00h Output data of Out14
Operation
Address 27h (Read/Write)
Description
D7-D0
(Out15)
Output data
Initial
value
00h Output data of Out15
Operation
Address 28h (Write)
Description
D0
(Irqc)
Clear the internal
interrupt
Initial
value
Operation
0 1: The internal interrupt is cleared.
Address 29h (Write)
Description
D0
(Send)
Start the transmission
Initial
value
Operation
1: The register setting is forwarded to the transmission buffer, and
0
the transmission starts in the IrRC (or IrTX) pin. After forwarding to
the transmission buffer, this bit is set “0”. At the same time, the
internal interrupt is cleared.
www.rohm.com
© 2015 ROHM Co., Ltd. All rights reserved.
TSZ22111・15・001
33/33
TSZ02201-0E4E0F100020-1-2
24. June. 2015 Rev.001